Exact-port documentation, explicit unknowns and transparent source-side power scenarios. No live network scan, purchasing rankings or installation approval.
Begin with the connection you are investigating
Eight network, fiber and RF questions
Separate the physical component from equipment service, optical requirements and the information still needed. These references do not approve an installation.
T06 · Document the actual path
Ethernet markings versus port and PoE capability
An 8P8C-style outline or cable category marking does not identify an Ethernet service or power role. Separate exact port function, the data path and any PoE requirement.
The existing worksheet models its own af/at and documented-profile scope. A word or connector shape does not establish arbitrary PoE or proprietary-power support.
RJ45 / 8-position modular product family · Revision not recorded · Recorded source inspection 2026-10-01. No independent hardware or human approval implied.
Interface / PoE power / Product diagram labels in accessible text · Revision not recorded · Recorded source inspection 2026-10-03. Only the documented data-in / power-data-out topology is modeled. No passive injector, splitter, multi-gig passthrough or mains-work advice.
PSE and PD terminology / Active and passive PoE · Revision not recorded · Recorded source inspection 2026-10-03. Manufacturer guidance, not a reproduced IEEE standard. Passive power and bt are outside this worksheet; no voltage or wiring prescription is provided.
PoE Modes: Type 1 and 2 / Lite family / Physical Security consumption · Revision not recorded · Recorded source inspection 2026-10-03. Only af/at rows are modeled; no bt values copied. G5 Bullet consumption conflicts with the exact datasheet's 4 W and remains unresolved.
T568A versus T568B pair-to-pin differences and diagram orientation note · Revision not recorded · Recorded source inspection 2026-10-05. Termination convention only. It does not establish that an 8P8C-shaped port is Ethernet, its link rate, PoE support or cable-category performance.
Questions 1, 6, 7; IEEE standards-based PoE, proprietary solutions and certification · Revision not recorded · Recorded source inspection 2026-10-15. A general article is not certification evidence for any unidentified port, PSE, PD, injector or supplied cable.
Three exact-equipment examples
These are source-backed documentation cases. They do not select your equipment, fill the form above, or report a hardware test.
T06-S1 · Supported within the stated documentation scope
One named PoE access point on a documented PoE+ port
Document a single U6+ powered data connection in normal switch mode.
Use TL-SG1005P V5 ports1-4 with its specified PSU; normal mode, healthy identified patch cable, one PD and known remaining budget.
Do not replace standard PoE negotiation with passive power or extend-mode assumptions.
TP-Link lists af/at PSE ports, 30W per port and65W aggregate; Ubiquiti lists PoE and9W maximum for U6+. M05-21 · M05-22
N6PATC1MBK is an exact 1m copper Cat6 patch cord, not a source of power or faster endpoint features. M05-25
Supported within the stated documentation scope: The documented powered-device/PSE roles and the stated one-device budget support this scoped documentation path. The link’s negotiated rate and delivered power have not been observed.
Next check: Record the actual PSE port, switch revision, other loads and cable before treating the installation record as complete.
Documentation scope only. This is not a hardware test, detected device state, pinout, electrical replacement approval or guarantee for another product/revision.
PDF pp.1-3: exact 1m Cat6 copper patch cord, network/PoE context; a cable does not create PSE power or a faster endpoint · No document revision shown on inspected page · Inspected 2026-10-22. Selected exact-model documentation only; no hardware test or broader family approval.
This example explicitly enables Extend Mode on a documented affected port.
TP-Link’s selected-version footnote reduces Extend Mode ports to10Mbps. Cat6 cable construction does not override that switch-mode restriction. M05-21 · M05-25
The proposed path disagrees with the documentation: The requested Gigabit data mode contradicts the selected switch setting, irrespective of the cable category marking.
Next check: Read the exact switch mode and requirements before interpreting the Ethernet cable label as an end-to-end rate.
Documentation scope only. This is not a hardware test, detected device state, pinout, electrical replacement approval or guarantee for another product/revision.
PDF pp.1-3: exact 1m Cat6 copper patch cord, network/PoE context; a cable does not create PSE power or a faster endpoint · No document revision shown on inspected page · Inspected 2026-10-22. Selected exact-model documentation only; no hardware test or broader family approval.
The number and maximum requirements of existing powered devices have not been recorded.
The switch lists52W total PoE availability and GbE ports; the U7 Pro lists PoE+ and21W maximum with a1/2.5GbE interface. M05-24 · M05-23
Specific information is still missing: The PSE/PD class alone does not settle the remaining power budget. The switch also does not acquire 2.5 GbE ports from the access point or Cat6 label.
Still needed:
Existing PoE load inventory and available aggregate budget
Actual cable/port condition and negotiated data rate
Next check: Inventory the actual PoE loads and operating requirements, then evaluate aggregate and per-port limits separately.
Documentation scope only. This is not a hardware test, detected device state, pinout, electrical replacement approval or guarantee for another product/revision.
Overview: eight GbE ports/four PoE+, 52W total PoE availability; per-port and overall budgets distinct · No document revision shown on inspected page · Inspected 2026-10-22. Selected exact-model documentation only; no hardware test or broader family approval.
PDF pp.1-3: exact 1m Cat6 copper patch cord, network/PoE context; a cable does not create PSE power or a faster endpoint · No document revision shown on inspected page · Inspected 2026-10-22. Selected exact-model documentation only; no hardware test or broader family approval.
Documentation and arithmetic only: not a compatibility, negotiated-rate, cable, delivered-power or installation approval. No hardware has been tested. Passive power, bt, SFP/fiber, custom pinouts, mains work and outdoor-installation design are outside this workflow. Independent technical review is pending.
SOURCE-QUALIFIED FIBER REFERENCE
The connector is not the complete path.
Eight examples separate identity, polish, pin state and optical mapping. Three previously unillustrated forms gain named-series studies.
Six named examples distinguish mating interface, panel mounting, board/cable termination and impedance. Missing fields and conflicting ratings remain explicit.