FIELD REFERENCE / TNC & RP-SMA
Keep the revision.
Separate the roles.
An identifiable part number is a start, not the whole specification. Read a historical TNC drawing without making it current. Read an RP-SMA jack label without guessing its center contact or shape.
01 / REVISION
A date belongs to the drawing.
The two TNC studies show 122108 revision B, dated 16 July 2008. Inspecting that drawing today does not make it a current revision.
02 / COMPONENTS
Loose parts stay separate.
The body, contact pin and ferrule are distinct drawing elements. The overview does not show an assembled cable or an installation sequence.
03 / CONTACT ROLE
A jack can have a male pin.
For 132134RP, the source descriptions separate jack role, center pin, standard thread direction and board termination. No physical view is inferred.
ONE HISTORICAL COMPONENT / TWO PHYSICAL VIEWS
A dated exterior,
not a current drawing.
P226 / Source-observed physical study
TNC 122108 / revision B body
Amphenol Connex 122108 / revision B / 2008-07-16
Side elevation: coupling end left, cable-side tail right · Cable plug / cable end
Historical 122108 revision B (2008-07-16), body only. Separate contact pin and ferrule omitted. Current geometry is unverified.
Not to scale. Technical and rights review pending.
Inspect view & provenance (private workspace)P226 / Source-observed physical study
TNC 122108 / revision B separate components
Amphenol Connex 122108 / revision B / 2008-07-16
Body, loose contact pin and ferrule shown separately; relative scale intentionally not shared · Cable plug / cable end
Historical 122108 revision B (2008-07-16). Components remain separate: not an assembled connector, cable-preparation sequence or fit template. Current geometry is unverified.
Not to scale. Technical and rights review pending.
Inspect view & provenance (private workspace)TNC gains its first registered specimen and source-observed physical view. Both illustrations are tied to the same historical drawing. No current-revision geometry, hidden contacts, dimensions or assembly instructions are supplied. All new views are supplementary; inherited lead images remain unchanged.
REVISION / ROLE / CONTACT / NEXT CHECK
Five checks. Two existing references.
Read the two references together → · Open the network desk →
| Reference example | Role & distinction | What is established | Unresolved / next check |
|---|---|---|---|
| TNC body / historical view122108 / revision B / 2008-07-16Inspect the dated view → (private workspace) | Body of a cable plug; loose parts not shown in this view. Knurled coupling region and a narrower stepped cable-side tail. | The inspected revision supports this qualitative body view.Evidence, revision & limitsObserved . C226F Amphenol Connex 122108 — historical revision B drawing ↗ Observation date is not drawing issue date. No hardware test, current-revision equivalence or independent approval. | Not established: Current dimensions, material and revision equivalence are unverified. Next check: Identify the revision supplied with the actual part before using engineering information. |
| TNC separated components122108 / revision B / 2008-07-16Inspect the dated view → (private workspace) | Body, contact pin and ferrule are distinct depicted components. The separate pin is not silently inserted into the body image. | The dated drawing distinguishes loose components from an assembly.Evidence, revision & limitsObserved . C226E Amphenol Connex 122108 — historical revision B drawing ↗ Observation date is not drawing issue date. No hardware test, current-revision equivalence or independent approval. | Not established: No assembled cable, crimp selection or preparation method is established. Next check: Use the exact current assembly instructions for any installation. |
| TNC revision / material disagreement122108 / historical drawing and current page No physical view is assigned to this evidence row. | Two source observations are not automatically equivalent. Drawing: Delrin. Current product page: PTFE. | An unresolved material difference is retained without selecting either value.Evidence, revision & limitsObserved . C226G Amphenol RF 122108 — current material field ↗ Amphenol Connex 122108 — historical revision B drawing ↗ Observation date is not drawing issue date. No hardware test, current-revision equivalence or independent approval. | Not established: No evidence here establishes which document governs a supplied component. Next check: Resolve the applicable drawing revision and material with the manufacturer. |
| RP-SMA role / thread / termination132134RP / exact product-page identity No physical view is assigned to this evidence row. | Jack with board through-hole termination; straight orientation. Threaded coupling, Standard thread direction; soldered contact. | These are separate manufacturer fields, not a visual mating decision.Evidence, revision & limitsAmphenol RF 132134RP — board-jack and thread fields ↗ Observation date is not drawing issue date. No hardware test, current-revision equivalence or independent approval. | Not established: Exact physical drawing and current geometry remain uninspected. Next check: Retain the full RP part number and obtain its exact drawing; do not use 132134 as a substitute. |
| RP-SMA contact / cross-reference boundary132134RP / TE competitor-description rows No physical view is assigned to this evidence row. | The TE rows pair the jack label with a male center pin. Center-contact form is separate from the jack designation. | The source supplies terminology, not an equivalence approval.Evidence, revision & limitsTE Connectivity Linx cross-reference — RP-SMA role labels and limits ↗ Observation date is not drawing issue date. No hardware test, current-revision equivalence or independent approval. | Not established: No TE replacement, unseen geometry or application compatibility is established. Next check: Read the guide disclaimer and verify exact part-specific requirements independently. |
P226 / SOURCE-QUALIFIED CHECK
TNC body / historical view
122108 / revision B / 2008-07-16
- Role
- Body of a cable plug; loose parts not shown in this view.
- Documented distinction
- Knurled coupling region and a narrower stepped cable-side tail.
- What is established
- The inspected revision supports this qualitative body view.
- Not established
- Current dimensions, material and revision equivalence are unverified.
- Next check
- Identify the revision supplied with the actual part before using engineering information.
Evidence, revision & limits
Observed . C226F
Amphenol Connex 122108 — historical revision B drawing ↗
Single page: drawing number 122108.DWG, revision B, issue date 07/16/08; body elevation, separate pin and ferrule, title block and materials table visually inspected.
S557 · canonical observation date 2026-10-12. Historical manufacturer-authored drawing, hosted by a distributor. Two qualitative views retain revision B / 2008-07-16. Current dimensional or material equivalence is unverified; installation dimensions are omitted.
Observation date is not drawing issue date. No hardware test, current-revision equivalence or independent approval.
P226 / SOURCE-QUALIFIED CHECK
TNC separated components
122108 / revision B / 2008-07-16
- Role
- Body, contact pin and ferrule are distinct depicted components.
- Documented distinction
- The separate pin is not silently inserted into the body image.
- What is established
- The dated drawing distinguishes loose components from an assembly.
- Not established
- No assembled cable, crimp selection or preparation method is established.
- Next check
- Use the exact current assembly instructions for any installation.
Evidence, revision & limits
Observed . C226E
Amphenol Connex 122108 — historical revision B drawing ↗
Single page: drawing number 122108.DWG, revision B, issue date 07/16/08; body elevation, separate pin and ferrule, title block and materials table visually inspected.
S557 · canonical observation date 2026-10-12. Historical manufacturer-authored drawing, hosted by a distributor. Two qualitative views retain revision B / 2008-07-16. Current dimensional or material equivalence is unverified; installation dimensions are omitted.
Observation date is not drawing issue date. No hardware test, current-revision equivalence or independent approval.
P226 / SOURCE-QUALIFIED CHECK
TNC revision / material disagreement
122108 / historical drawing and current page
- Role
- Two source observations are not automatically equivalent.
- Documented distinction
- Drawing: Delrin. Current product page: PTFE.
- What is established
- An unresolved material difference is retained without selecting either value.
- Not established
- No evidence here establishes which document governs a supplied component.
- Next check
- Resolve the applicable drawing revision and material with the manufacturer.
No physical view is assigned to this evidence row.
Evidence, revision & limits
Observed . C226G
Amphenol RF 122108 — current material field ↗
Product Specifications: Insulator Material, component role and termination fields.
S556 · canonical observation date 2026-10-12. The observed product page lists PTFE. This disagrees with the Delrin entry in the separately acquired revision B drawing; no resolution or supersession is established.
Amphenol Connex 122108 — historical revision B drawing ↗
Single page: drawing number 122108.DWG, revision B, issue date 07/16/08; body elevation, separate pin and ferrule, title block and materials table visually inspected.
S557 · canonical observation date 2026-10-12. Historical manufacturer-authored drawing, hosted by a distributor. Two qualitative views retain revision B / 2008-07-16. Current dimensional or material equivalence is unverified; installation dimensions are omitted.
Observation date is not drawing issue date. No hardware test, current-revision equivalence or independent approval.
P064 / SOURCE-QUALIFIED CHECK
RP-SMA role / thread / termination
132134RP / exact product-page identity
- Role
- Jack with board through-hole termination; straight orientation.
- Documented distinction
- Threaded coupling, Standard thread direction; soldered contact.
- What is established
- These are separate manufacturer fields, not a visual mating decision.
- Not established
- Exact physical drawing and current geometry remain uninspected.
- Next check
- Retain the full RP part number and obtain its exact drawing; do not use 132134 as a substitute.
No physical view is assigned to this evidence row.
Evidence, revision & limits
Amphenol RF 132134RP — board-jack and thread fields ↗
Exact part heading; Product Specifications: Gender, Coupling, Thread Direction, Orientation, Termination Style and Contact Termination.
S558 · canonical observation date 2026-10-12. Part-specific jack role, standard thread direction and PCB through-hole solder termination. Linked drawing could not be visually inspected; no physical geometry is inferred.
Observation date is not drawing issue date. No hardware test, current-revision equivalence or independent approval.
P064 / SOURCE-QUALIFIED CHECK
RP-SMA contact / cross-reference boundary
132134RP / TE competitor-description rows
- Role
- The TE rows pair the jack label with a male center pin.
- Documented distinction
- Center-contact form is separate from the jack designation.
- What is established
- The source supplies terminology, not an equivalence approval.
- Not established
- No TE replacement, unseen geometry or application compatibility is established.
- Next check
- Read the guide disclaimer and verify exact part-specific requirements independently.
No physical view is assigned to this evidence row.
Evidence, revision & limits
TE Connectivity Linx cross-reference — RP-SMA role labels and limits ↗
Printed page 5: the two Amphenol 132134RP rows; printed page 2: disclaimer. Both pages visually inspected.
S559 · canonical observation date 2026-10-12. The competitor-description rows identify a jack with a male pin. TE explicitly does not assert exact equivalence; this guide is not a replacement approval or a source for uninspected geometry.
Observation date is not drawing issue date. No hardware test, current-revision equivalence or independent approval.
EXPLICIT SOURCE DIFFERENCE / NO SELECTED MATERIAL
Historical Delrin.
Current page: PTFE.
The revision B drawing lists Delrin for the 122108 insulator. The product page inspected on 12 October 2026 lists PTFE. No evidence reviewed here resolves the difference. Neither value is imported into an engineering profile or assigned to an unknown supplied part.
Historical drawing / S557 ↗ · Current material field / S556 ↗
The requested current manufacturer drawing remains uninspected. The historical study is useful additional evidence, not a claim that the current drawing request is fully closed.
RP-SMA / ROLE LABELS ARE NOT GEOMETRY
Four fields,
no substitute silhouette.
TE’s 132134RP rows distinguish a jack from its male center pin. The guide also warns that its cross-references do not establish exact equivalence. No TE replacement or ordinary 132134 image is used to fill the missing exact RP-SMA view.
FIELD OUTPUT / FOUR PAGES / REVISION RETAINED
Keep the evidence with the part.
Two historical physical views, one source-field concept, five evidence checks and the complete source ledger.
Letter PDF · 4 pages ↓ (legacy download held for current evidence review). Current focused printable referencesA4 PDF · 4 pages ↓ (legacy download held for current evidence review). Current focused printable referencesStill open
Current 122108 drawing equivalence and the exact 132134RP physical drawing remain unresolved. Earlier power, optical and coaxial image requests remain in the backlog. Seven canonical claims and four source observations deepen two existing references; no new connector form is counted. No independent technical or rights certification or hardware testing is claimed. Review the measured gaps →