FIELD GUIDESource-led reference

P180 / Power / Connector

IEC 60320 C14 appliance inlet

IEC 60320 C14 is an appliance inlet commonly mated by a C13 cord connector.

Also called C14 IEC C14 computer power inlet

An inlet outline does not establish the connected equipment rating or approved cord set.

Look for

Confirm that the equipment side is the C14 inlet and verify the appliance nameplate before choosing a mating cord.

Claim inspection dates: 2026-10-05, 2026-10-13, 2026-10-22 · Independent review pending

Image inspection / P180

See the view. Check its scope.

1 registered view for this reference. Different part examples are not automatically mates; all remain not to scale and independently unapproved.

Original qualitative, deliberately simplified exterior for SCHURTER 6100-3 / 6100.3200; IEC C14 Appliance inlet, 70°C source example. No gauge shape, wiring or safe-fit approval. (private workspace)

P180 / Source-observed physical study

IEC C14 · inlet

SCHURTER 6100-3 / 6100.3200

simplified manufacturer product-photo exterior · Appliance inlet

Not to scale. Technical and rights review pending.

Inspect view & provenance (private workspace)

The useful distinction

Recognize it. Then verify it.

IEC 60320 C14 is an appliance inlet commonly mated by a C13 cord connector. [C180A]

SCHURTER 6100-3 is catalogued as an IEC C14 appliance inlet; the observed product photos and datasheet identify an equipment-side component, not both ends of a mains cord. [C180B]

The SCHURTER 6100-3 datasheet identifies a 70°C pin-temperature classification; this is a part/series rating under documented conditions, not an automatic rating for an appliance, installed cord or alternate product. [C180C]

SCHURTER's documented IEC C14 product family identifies the complementary C13 form in the cited mating-product references. Confirm the actual variants and full installed equipment/cordset documentation; no safe-fit or cable-load approval follows solely from that relationship. [C180D]

Exact source example 6100.3200: construction: Screw-on front/rear panel inlet; 4.8 x0.8 mm quick-connect terminals; protection class I. pin temperature c: 70. rating: IEC10 A; UL/CSA15 A at250 VAC. Exact listed order number; regional ratings remain distinct. No physical compatibility, pin map or hardware validation is established. [C180E]

Source-scoped identification facts

Each value retains its exact example, role and measurement axis. Facts from different parts must not be combined into an invented component.

Documented examples; not a mating drawing or compatibility approval
Connector roleplug (6100.3200)S585Named source examples retain separate role, part, view and axis limits; values are not a universal family specification. 6100.3200. Documented role: plug. Full PDF text read; direct download403. Diagram numbers have no verified axes here; no geometry or visible specimen marking proposed.
ManufacturerSCHURTER (6100.3200)S585Named source examples retain separate role, part, view and axis limits; values are not a universal family specification. 6100.3200. Documented role: plug. Full PDF text read; direct download403. Diagram numbers have no verified axes here; no geometry or visible specimen marking proposed.
Series6100-3 (6100.3200)S585Named source examples retain separate role, part, view and axis limits; values are not a universal family specification. 6100.3200. Documented role: plug. Full PDF text read; direct download403. Diagram numbers have no verified axes here; no geometry or visible specimen marking proposed.
Exact part / implementation6100.3200 (6100.3200)S585Named source examples retain separate role, part, view and axis limits; values are not a universal family specification. 6100.3200. Documented role: plug. Full PDF text read; direct download403. Diagram numbers have no verified axes here; no geometry or visible specimen marking proposed.

Not recorded: Nominal contacts, Positions / cavity span, Populated contacts, Contact rows, Contact pitch, Dimensions / axis, Contact gender / arrangement, Mounting, Coupling / latch, Keying / polarization, Shell / form, Recorded markings, View convention. Unknown fields stay unknown; illustrations supply no measurements or pin assignments.

Report a correction to these facts →

Bounded facts, visible unknowns

Specifications and limits

IEC 60320 C14 appliance inlet facts and limitations
Documented identificationAppliance inlet in the C13/C14 IEC 60320 pair. [C180A]
Observed manufacturer exampleSCHURTER 6100-3 / 6100.3200 · Appliance inlet · 70°C source example. Specific product family only; not a full cordset or installed device rating. [C180B] [C180C]
Example mating designationC14 / C13 pair listed in manufacturer references; select only with complete product and appliance documentation. [C180D]
Mechanical dimensionsNo independently reviewed mechanical drawing in V36; do not use this page for fabrication, fit testing or tolerance work.
Engineering pinoutSource-checked engineering profile available; independent review pending. Open engineering profile →
Verified device listNot included. Check exact device and accessory documentation.
No electrical replacement approval.

Use the source-backed form or position count only for identification. Resolve ratings, protocol, direction, wiring, cable construction and exact device support from the relevant equipment and component documentation.

Before you connect

What to check

  1. Identify the exact connector family and variant from the equipment or cable documentation.
  2. Keep shape, contact count, protocol, electrical rating and device support as separate facts.
  3. Do not force, rewire or adapt a connector from this recognition record; resolve the remaining requirements first.
Trace a supported connection class →

What is not established

This field note does not approve a connection, adapter, cable assembly, rewiring scheme or fabricated part. It intentionally omits unsupported pin assignments and mechanical tolerances.

V141 manufacturer example and safe interpretation

Screw-mounted equipment inlet, not a cord connector. Read equipment inlet designation and nameplate; inspect whether sealing kit is present. Not established: Equipment rating, sealing status of the installed variant and approved cordset. Refer to source S585; no wiring, electrical installation or fit is certified.

Your next step

Move from the form to the requirement.

The source trail

Evidence for this page

AI-assisted inspection is not independent engineering review. Source scope and access limitations are disclosed below. Procedural checklists are editorial requirements, not hardware measurements.

Back to first citation ↑
C180ASource checked · pending review

Interpower identifies C14 as the appliance-inlet side of the C13/C14 IEC 60320 appliance-coupler pairing.

Interpower · IEC 60320 appliance couplers — featured product overview ↗

Locator: IEC 60320 appliance coupler product families and mating-pair overview
Access: public page. Identification/reference scope only. V36 does not convert this source into a universal pinout, fabrication drawing, electrical approval or end-to-end compatibility verdict.

S195: full source recordInspect review dependencies → (private workspace)

Claim scope: V36 catalogue-expansion identification fact only; not independent technical approval, fabrication data, wiring instruction or end-to-end compatibility proof.. Next review due 2027-01-03.

Back to first citation ↑
C180BSource checked · pending review

SCHURTER 6100-3 is catalogued as an IEC C14 appliance inlet; the observed product photos and datasheet identify an equipment-side component, not both ends of a mains cord.

SCHURTER · SCHURTER 6100-3 / 6100.3200 — IEC C14 manufacturer datasheet ↗

Locator: PDF p.1 panel-mount inlet, pin temperature 70°C, IP54 option description; p.4 mating connector list; visually inspected p.1 product photos.
Access: public pdf text. Variant-specific geometry and ratings. Not a generic IEC designation approval, safe mating rule, wiring map, cordset certification or fabrication dimension.

S585: full source recordInspect review dependencies → (private workspace)

Claim scope: V141 manufacturer-specific IEC mains connector identity, coupling-family example, and thermal classification. NOT installation, cordset approval, dimension, pinout, universal fit, regional plug rating or safe electrical use.. Next review due 2027-01-11.

Back to first citation ↑
C180CSource checked · pending review

The SCHURTER 6100-3 datasheet identifies a 70°C pin-temperature classification; this is a part/series rating under documented conditions, not an automatic rating for an appliance, installed cord or alternate product.

SCHURTER · SCHURTER 6100-3 / 6100.3200 — IEC C14 manufacturer datasheet ↗

Locator: PDF p.1 panel-mount inlet, pin temperature 70°C, IP54 option description; p.4 mating connector list; visually inspected p.1 product photos.
Access: public pdf text. Variant-specific geometry and ratings. Not a generic IEC designation approval, safe mating rule, wiring map, cordset certification or fabrication dimension.

S585: full source recordInspect review dependencies → (private workspace)

Claim scope: V141 manufacturer-specific IEC mains connector identity, coupling-family example, and thermal classification. NOT installation, cordset approval, dimension, pinout, universal fit, regional plug rating or safe electrical use.. Next review due 2027-01-11.

Back to first citation ↑
C180DSource checked · pending review

SCHURTER's documented IEC C14 product family identifies the complementary C13 form in the cited mating-product references. Confirm the actual variants and full installed equipment/cordset documentation; no safe-fit or cable-load approval follows solely from that relationship.

SCHURTER · SCHURTER 6100-3 / 6100.3200 — IEC C14 manufacturer datasheet ↗

Locator: PDF p.1 panel-mount inlet, pin temperature 70°C, IP54 option description; p.4 mating connector list; visually inspected p.1 product photos.
Access: public pdf text. Variant-specific geometry and ratings. Not a generic IEC designation approval, safe mating rule, wiring map, cordset certification or fabrication dimension.

S585: full source recordInspect review dependencies → (private workspace)

Claim scope: V141 manufacturer-specific IEC mains connector identity, coupling-family example, and thermal classification. NOT installation, cordset approval, dimension, pinout, universal fit, regional plug rating or safe electrical use.. Next review due 2027-01-11.

Back to first citation ↑
C180ESource checked · pending review

Exact source example 6100.3200: construction: Screw-on front/rear panel inlet; 4.8 x0.8 mm quick-connect terminals; protection class I. pin temperature c: 70. rating: IEC10 A; UL/CSA15 A at250 VAC. Exact listed order number; regional ratings remain distinct. No physical compatibility, pin map or hardware validation is established.

SCHURTER · SCHURTER 6100-3 / 6100.3200 — IEC C14 manufacturer datasheet ↗

Locator: PDF p.1 panel-mount inlet, pin temperature 70°C, IP54 option description; p.4 mating connector list; visually inspected p.1 product photos.
Access: public pdf text. Variant-specific geometry and ratings. Not a generic IEC designation approval, safe mating rule, wiring map, cordset certification or fabrication dimension.

S585: full source recordInspect review dependencies → (private workspace)

Claim scope: Exact named component/family technical construction reference from the full current primary document; geometry, ratings and implementation limits do not transfer to other variants.. Next review due 2027-01-20.

Suggest a correction to this field note →

Put this field note to work.

Add to discovery trayRecord an unsaved candidate (private workspace)

Compare look-alikes: IEC C14 versus C16 appliance inlets

Candidate selection does not confirm the identity or capabilities of your physical item.

Evidence behind this page

Scope first. Source second. Approval separate.

2 linked sources · 5 scoped claims · 0 sources with inspection/access flags.

Page scope: catalogue_expansion_v36; v141_iec_manufacturer_comparison

Assessment 2026-10-22 · earliest scheduled source review 2027-01-03. This is a recorded-date assessment, not a live source check. Page-level independent review is not established by this panel.

Inspect 2 source scopes, access limits and dates

S195 · IEC 60320 appliance couplers — featured product overview

Interpower · Manufacturer / product-owner domain · inspected 2026-10-05 · due 2027-01-03

Within inspection window

Scoped support: Identifies common IEC 60320 C13/C14, C15/C16 and C19/C20 connector/inlet pairings and distinguishes the cord connector from the appliance inlet.

Not established / limitations: Identification/reference scope only. V36 does not convert this source into a universal pinout, fabrication drawing, electrical approval or end-to-end compatibility verdict.

Locator: IEC 60320 appliance coupler product families and mating-pair overview

S585 · SCHURTER 6100-3 / 6100.3200 — IEC C14 manufacturer datasheet

SCHURTER · Manufacturer / product-owner domain · inspected 2026-10-13 · due 2027-01-11

Within inspection window

Scoped support: Specific named rewireable connector or panel inlet; identification and manufacturer variant details, not a full cable/device approval or standardized geometry.

Not established / limitations: Variant-specific geometry and ratings. Not a generic IEC designation approval, safe mating rule, wiring map, cordset certification or fabrication dimension.

Locator: PDF p.1 panel-mount inlet, pin temperature 70°C, IP54 option description; p.4 mating connector list; visually inspected p.1 product photos.

Trace 5 claims to their source records

C180A · P180

Interpower identifies C14 as the appliance-inlet side of the C13/C14 IEC 60320 appliance-coupler pairing.

Claim scope: V36 catalogue-expansion identification fact only; not independent technical approval, fabrication data, wiring instruction or end-to-end compatibility proof.

Source links: S195 · Evidence trail → (private workspace)

C180B · P180

SCHURTER 6100-3 is catalogued as an IEC C14 appliance inlet; the observed product photos and datasheet identify an equipment-side component, not both ends of a mains cord.

Claim scope: V141 manufacturer-specific IEC mains connector identity, coupling-family example, and thermal classification. NOT installation, cordset approval, dimension, pinout, universal fit, regional plug rating or safe electrical use.

Source links: S585 · Evidence trail → (private workspace)

C180C · P180

The SCHURTER 6100-3 datasheet identifies a 70°C pin-temperature classification; this is a part/series rating under documented conditions, not an automatic rating for an appliance, installed cord or alternate product.

Claim scope: V141 manufacturer-specific IEC mains connector identity, coupling-family example, and thermal classification. NOT installation, cordset approval, dimension, pinout, universal fit, regional plug rating or safe electrical use.

Source links: S585 · Evidence trail → (private workspace)

C180D · P180

SCHURTER's documented IEC C14 product family identifies the complementary C13 form in the cited mating-product references. Confirm the actual variants and full installed equipment/cordset documentation; no safe-fit or cable-load approval follows solely from that relationship.

Claim scope: V141 manufacturer-specific IEC mains connector identity, coupling-family example, and thermal classification. NOT installation, cordset approval, dimension, pinout, universal fit, regional plug rating or safe electrical use.

Source links: S585 · Evidence trail → (private workspace)

C180E · P180

Exact source example 6100.3200: construction: Screw-on front/rear panel inlet; 4.8 x0.8 mm quick-connect terminals; protection class I. pin temperature c: 70. rating: IEC10 A; UL/CSA15 A at250 VAC. Exact listed order number; regional ratings remain distinct. No physical compatibility, pin map or hardware validation is established.

Claim scope: Exact named component/family technical construction reference from the full current primary document; geometry, ratings and implementation limits do not transfer to other variants.

Source links: S585 · Evidence trail → (private workspace)

Prepare this page for review → (private workspace)Read the evidence method →

Recorded evidence only. An inspection date, publisher label, source link or generated packet is not independent technical review, hardware testing, fabrication approval or a compatibility verdict.