8 linked sources · 13 scoped claims · 0 sources with inspection/access flags.
Assessment 2026-10-22 · earliest scheduled source review 2027-01-03. This is a recorded-date assessment, not a live source check. Page-level independent review is not established by this panel.
Inspect 8 source scopes, access limits and dates
Interpower · Manufacturer / product-owner domain · inspected 2026-10-05 · due 2027-01-03
Within inspection window
Scoped support: Identifies common IEC 60320 C13/C14, C15/C16 and C19/C20 connector/inlet pairings and distinguishes the cord connector from the appliance inlet.
Not established / limitations: Identification/reference scope only. V36 does not convert this source into a universal pinout, fabrication drawing, electrical approval or end-to-end compatibility verdict.
Locator: IEC 60320 appliance coupler product families and mating-pair overview
Interpower · Manufacturer / product-owner domain · inspected 2026-10-05 · due 2027-01-03
Within inspection window
Scoped support: Identifies C17/C18 as a Class II, non-grounded IEC 60320 appliance-coupler pair.
Not established / limitations: Identification/reference scope only. V39 does not convert this source into a universal pinout, fabrication drawing, electrical approval, protocol guarantee or end-to-end compatibility verdict.
Locator: C17 connector and C18 inlet section
Interpower · Manufacturer / product-owner domain · inspected 2026-10-05 · due 2027-01-03
Within inspection window
Scoped support: Engineering scope: C17/C18 are identified as a Class II pair for applications not requiring a ground path.
Not established / limitations: Engineering-reference scope only. V40 does not turn this source into fabrication approval, electrical safety approval, protocol guarantee, safe substitution or end-to-end compatibility proof.
Locator: C17 Connector and C18 Inlet
SCHURTER · Manufacturer / product-owner domain · inspected 2026-10-05 · due 2027-01-03
Within inspection window
Scoped support: Engineering boundary: IEC 60320 appliance couplers are treated as two-pole couplers with or without a protective conductor; V40 uses this only to avoid inventing extra contacts on non-grounded pairs.
Not established / limitations: Engineering-reference scope only. V40 does not turn this source into fabrication approval, electrical safety approval, protocol guarantee, safe substitution or end-to-end compatibility proof.
Locator: IEC appliance-coupler overview
SCHURTER · Manufacturer / product-owner domain · inspected 2026-10-13 · due 2027-01-11
Within inspection window
Scoped support: Specific named rewireable connector or panel inlet; identification and manufacturer variant details, not a full cable/device approval or standardized geometry.
Not established / limitations: Variant-specific geometry and ratings. Not a generic IEC designation approval, safe mating rule, wiring map, cordset certification or fabrication dimension.
Locator: PDF p.1 description and cold-condition classification; pp.3–4 mating inlets; visually inspected PDF p.1 product photos and C13 icon.
SCHURTER · Manufacturer / product-owner domain · inspected 2026-10-13 · due 2027-01-11
Within inspection window
Scoped support: Named North American cord assembly only. Cord-set ratings and the inlet/component classification are different scopes; no universal C17 rating or system approval.
Not established / limitations: Named North American cord assembly only. Cord-set ratings and the inlet/component classification are different scopes; no universal C17 rating or system approval. Available web text and rendered source pages inspected. Raw manufacturer file retention and byte hashes are not claimed.
Locator: Named part identification, technical data and exact variant row; page dated 01.09.2025.
SCHURTER · Manufacturer / product-owner domain · inspected 2026-10-13 · due 2027-01-11
Within inspection window
Scoped support: Original qualitative study of the named cord-end photograph, not a front-face engineering drawing or the small standardized icon. The release control and two openings are recognition cues; cable markings, internals and locking geometry are omitted.
Not established / limitations: Original qualitative study of the named cord-end photograph, not a front-face engineering drawing or the small standardized icon. The release control and two openings are recognition cues; cable markings, internals and locking geometry are omitted. Available web text and rendered source pages inspected. Raw manufacturer file retention and byte hashes are not claimed.
Locator: Page 1: oblique C17-end photograph and ratings; page 2: exact 3-101-794 variant and V-Lock note; page 3: issue date. All three pages visually inspected.
SCHURTER · Manufacturer / product-owner domain · inspected 2026-10-22 · due 2027-01-20
Within inspection window
Scoped support: Current primary-document research for P215 / 3-101-794. Each normalized fact retains its exact part/family, role and document scope.
Not established / limitations: No independent technical review, hardware validation, specimen measurement or general interoperability approval. Exact scopes and unresolved fields remain controlling.
Locator: pp.1–2description,technicaldata,V-Lock,variants
Trace 13 claims to their source records
C179A · P179
Interpower identifies C13 as the cord-connector side of the C13/C14 IEC 60320 appliance-coupler pairing.
Claim scope: V36 catalogue-expansion identification fact only; not independent technical approval, fabrication data, wiring instruction or end-to-end compatibility proof.
Source links: S195 · Evidence trail → (private workspace)
C179B · P179
SCHURTER 4782 is catalogued as an IEC C13 cord connector; the observed product photos and datasheet identify a cable-side component, not both ends of a mains cord.
Claim scope: V141 manufacturer-specific IEC mains connector identity, coupling-family example, and thermal classification. NOT installation, cordset approval, dimension, pinout, universal fit, regional plug rating or safe electrical use.
Source links: S584 · Evidence trail → (private workspace)
C179C · P179
The SCHURTER 4782 datasheet identifies a 70°C pin-temperature classification; this is a part/series rating under documented conditions, not an automatic rating for an appliance, installed cord or alternate product.
Claim scope: V141 manufacturer-specific IEC mains connector identity, coupling-family example, and thermal classification. NOT installation, cordset approval, dimension, pinout, universal fit, regional plug rating or safe electrical use.
Source links: S584 · Evidence trail → (private workspace)
C179D · P179
SCHURTER's documented IEC C13 product family identifies the complementary C14 form in the cited mating-product references. Confirm the actual variants and full installed equipment/cordset documentation; no safe-fit or cable-load approval follows solely from that relationship.
Claim scope: V141 manufacturer-specific IEC mains connector identity, coupling-family example, and thermal classification. NOT installation, cordset approval, dimension, pinout, universal fit, regional plug rating or safe electrical use.
Source links: S584 · Evidence trail → (private workspace)
C179W · P179
SCHURTER 4782 is a straight rewireable C13 cord connector with screw-on mounting, a thermoplastic housing rated UL 94V-0 and Protection Class I construction.
Claim scope: Exact SCHURTER 4782.0000 black straight rewireable C13 example; series 4782 construction and ratings only, separate from an installed cordset.
Source links: S584 · Evidence trail → (private workspace)
C179X · P179
The 4782 datasheet distinguishes 70 °C pin temperature from allowable operation of −25 °C to 70 °C. It lists IEC 10 A / 250 VAC / 50 Hz separately from UL/CSA 15 A / 250 VAC / 60 Hz component ratings.
Claim scope: Exact SCHURTER 4782.0000 black straight rewireable C13 example; series 4782 construction and ratings only, separate from an installed cordset.
Source links: S584 · Evidence trail → (private workspace)
C179Y · P179
The exact black 4782.0000 variant recommends 8.5 mm cable diameter and lists maximum conductor acceptance as IEC 3 × 1 mm² or UL 3 × 18 AWG.
Claim scope: Exact SCHURTER 4782.0000 black straight rewireable C13 example; series 4782 construction and ratings only, separate from an installed cordset.
Source links: S584 · Evidence trail → (private workspace)
C215A · P215
Interpower identifies C17 cord connector within the documented non-grounded C17/C18 IEC 60320 appliance-coupler pair.
Claim scope: V39 catalogue-expansion identification fact only; not independent technical approval, fabrication data, wiring instruction, protocol guarantee or end-to-end compatibility proof.
Source links: S221 · Evidence trail → (private workspace)
C215B · P215
Interpower identifies C17/C18 as a Class II pair for applications not requiring a ground path; V40 normalizes that as a two-pole, no-protective-earth boundary.
Claim scope: V40 engineering-reference fact only; independent human review remains pending. This claim does not approve fabrication, rewiring, substitution, electrical safety, protocol support or end-to-end compatibility.
Source links: S244 · S245 · Evidence trail → (private workspace)
C215C · P215
SCHURTER identifies 3-101-794 as a molded C17 V-Lock cord set with a North American NEMA 1-15 plug, 3.0 m black SJT 2x18 AWG cable.
Claim scope: Exact 3-101-794 assembly identification only; not all C17 cables, a bare connector, a rewireable kit or an adapter recommendation.
Source links: S630 · S631 · Evidence trail → (private workspace)
C215D · P215
The 3-101-794 technical-data row states a UL/CSA rating of 10 A / 125 VAC at 50/60 Hz.
Claim scope: Named complete cord assembly and specified approval scope only. An inlet or family-level 250 VAC value cannot be transferred to this cord; equipment and supply suitability remain unresolved.
Source links: S630 · S631 · Evidence trail → (private workspace)
C215E · P215
The 3-101-794 datasheet photograph shows two recessed openings on the C17 cord end and a visible top release control; its V-Lock note requires a matching retention combination.
Claim scope: Photo-observed oblique recognition only. No straight-on or measured mating geometry is inferred from the symbol, and a visible button does not prove locking compatibility with an unspecified inlet.
Source links: S631 · Evidence trail → (private workspace)
C215F · P215
Exact source example 3-101-794: construction: Cordset C17 moulded connector;V-Lock retention;protection class II;black PVC housing. rating: UL/CSA10A125VAC50/60Hz. pin temperature c: 70. Full current official document text read. No numeric axes adopted from unviewed diagrams.; Cordset cable length and wire gauge are excluded from connector envelope. Pin-temperature class differs from allowed ambient operating range.; Regulatory declaration/certificate references do not prove a literal moulded approval mark on an individual product. No physical compatibility, pin map or hardware validation is established.
Claim scope: Exact named component/family technical construction reference from the full current primary document; geometry, ratings and implementation limits do not transfer to other variants.
Source links: S927 · Evidence trail → (private workspace)
Recorded evidence only. An inspection date, publisher label, source link or generated packet is not independent technical review, hardware testing, fabrication approval or a compatibility verdict.