6 linked sources · 9 scoped claims · 0 sources with inspection/access flags.
Assessment 2026-10-22 · earliest scheduled source review 2027-01-03. This is a recorded-date assessment, not a live source check. Page-level independent review is not established by this panel.
Inspect 6 source scopes, access limits and dates
Interpower · Manufacturer / product-owner domain · inspected 2026-10-05 · due 2027-01-03
Within inspection window
Scoped support: Identifies common IEC 60320 C13/C14, C15/C16 and C19/C20 connector/inlet pairings and distinguishes the cord connector from the appliance inlet.
Not established / limitations: Identification/reference scope only. V36 does not convert this source into a universal pinout, fabrication drawing, electrical approval or end-to-end compatibility verdict.
Locator: IEC 60320 appliance coupler product families and mating-pair overview
Interpower · Manufacturer / product-owner domain · inspected 2026-10-06 · due 2027-01-04
Within inspection window
Scoped support: Identification of the C21 connector/C22 inlet pair and its named IEC 60320 coupler family only; no wiring or installation guidance.
Not established / limitations: Source-backed identification does not establish universal wiring, protocol generation, device compatibility, safe installation or fabrication approval.
Locator: IEC 60320 appliance-coupler family overview
SCHURTER · Manufacturer / product-owner domain · inspected 2026-10-13 · due 2027-01-11
Within inspection window
Scoped support: Specific named rewireable connector or panel inlet; identification and manufacturer variant details, not a full cable/device approval or standardized geometry.
Not established / limitations: Variant-specific geometry and ratings. Not a generic IEC designation approval, safe mating rule, wiring map, cordset certification or fabrication dimension.
Locator: PDF p.1 cord connector product photos, 16 A IEC component rating and 70°C classification; p.3 named C20 mating inlets.
Interpower · Manufacturer / product-owner domain · inspected 2026-10-22 · due 2027-01-20
Within inspection window
Scoped support: Historical manufacturer chart: named form roles, class/temperature family and explicit non-rewireable labels only.
Not established / limitations: Not the current normative IEC standard, measured specimen, dimensional drawing, universal wiring/contact-population statement or safety/mating approval. The rightmost interconnection columns are distinct roles.
Locator: One-page chart, Rev10-17; Connectors/Inlets columns, C1/C2,C9/C10,C15A/C16A,C21/C22,C23/C24 rows. Actual savedPDF text and150dpi pixels inspected.
Bulgin · Unclassified publisher domain · inspected 2026-10-22 · due 2027-01-20
Within inspection window
Scoped support: Manufacturer educational overview: stated conductor counts/temperature context and odd/even role nomenclature; no terminal positions.
Not established / limitations: Full public page read. Conductor counts are not silently converted into normalized contact positions, actual population or wiring maps. Not a normative mechanical specification; unrelated cable-length/generalized approval prose excluded.
Locator: How are IEC connectors named; named C1/C2,C9/C10,C15A/C16A,C21/C22,C23/C24 paragraphs.
SCHURTER · Manufacturer / product-owner domain · inspected 2026-10-22 · due 2027-01-20
Within inspection window
Scoped support: Exact1658.0000 straightC21 cord connector
Not established / limitations: Direct download403. Textual dimensions used only when the axis is explicitly named, such as panel thickness or terminal length. Unviewed outline numbers/pitch are not imported. Exact part, role, terminal and historical/current document scopes remain separate.
Locator: p.1Description/TechnicalData;p.2exact1658.0000 row;p.3matingtypes/date; complete3-page public PDF text read through official web retrieval; drawing pixels NOT acquired.
Trace 9 claims to their source records
C183A · P183
Interpower identifies C19 as the cord-connector side of the C19/C20 IEC 60320 appliance-coupler pairing.
Claim scope: V36 catalogue-expansion identification fact only; not independent technical approval, fabrication data, wiring instruction or end-to-end compatibility proof.
Source links: S195 · Evidence trail → (private workspace)
C183B · P183
SCHURTER 4795 is catalogued as an IEC C19 larger cord connector; the observed product photos and datasheet identify a cable-side component, not both ends of a mains cord.
Claim scope: V141 manufacturer-specific IEC mains connector identity, coupling-family example, and thermal classification. NOT installation, cordset approval, dimension, pinout, universal fit, regional plug rating or safe electrical use.
Source links: S588 · Evidence trail → (private workspace)
C183C · P183
The SCHURTER 4795 datasheet identifies a 70°C pin-temperature classification; this is a part/series rating under documented conditions, not an automatic rating for an appliance, installed cord or alternate product.
Claim scope: V141 manufacturer-specific IEC mains connector identity, coupling-family example, and thermal classification. NOT installation, cordset approval, dimension, pinout, universal fit, regional plug rating or safe electrical use.
Source links: S588 · Evidence trail → (private workspace)
C183D · P183
SCHURTER's documented IEC C19 product family identifies the complementary C20 form in the cited mating-product references. Confirm the actual variants and full installed equipment/cordset documentation; no safe-fit or cable-load approval follows solely from that relationship.
Claim scope: V141 manufacturer-specific IEC mains connector identity, coupling-family example, and thermal classification. NOT installation, cordset approval, dimension, pinout, universal fit, regional plug rating or safe electrical use.
Source links: S588 · Evidence trail → (private workspace)
C183E · P183
Exact source example 4795.0000: construction: Straight rewireable cable-mounted C19 connector; black housing; protection class I. pin temperature c: 70. rating: IEC16 A; UL/CSA20 A at250 VAC. Exact listed order number; regional ratings remain distinct. No physical compatibility, pin map or hardware validation is established.
Claim scope: Exact named component/family technical construction reference from the full current primary document; geometry, ratings and implementation limits do not transfer to other variants.
Source links: S588 · Evidence trail → (private workspace)
C305A · P305
Interpower’s IEC 60320 overview identifies the C21 connector with the C22 inlet in the Class I 16 A/20 A coupler family.
Claim scope: V50 IEC appliance-coupler identification fact only; no wiring, energized-work, circuit selection, interchangeability, installation or safe-operation approval is inferred.
Source links: S346 · Evidence trail → (private workspace)
C305B · P305
Interpower's Rev10-17 chart labels C21 as the cord connector paired with C22, in its Class I very hot group.
Claim scope: Interpower Rev10-17 labelled C21 cord connector family; no exact manufacturer part
Source links: S940 · Evidence trail → (private workspace)
C305C · P305
Bulgin's manufacturer overview describes the C21/C22 family as a 3-conductor system with 155 degrees C temperature context. This is not a terminal-position map.
Claim scope: Manufacturer educational family context; not actual population,positions,wholecordsuitability or current normative dimensional coverage.
Source links: S941 · Evidence trail → (private workspace)
C305D · P305
SCHURTER identifies 1658.0000 as follows: Straight rewireable C21 cord connector; screw clamps; black thermoplastic housing.
Claim scope: ExactSCHURTER 1658.0000 /series1658 only;termination dimensions are not mating pitch and no arbitraryequipment compatibility is asserted.
Source links: S944 · Evidence trail → (private workspace)
Recorded evidence only. An inspection date, publisher label, source link or generated packet is not independent technical review, hardware testing, fabrication approval or a compatibility verdict.