FIELD GUIDESource-led reference

E208 · Source-scoped pinout variants

8-pole speakON loudspeaker connector engineering reference

Eight-pole loudspeaker-connector identity only; amplifier channel assignment remains system-specific.

Source checked · no independent review claimed · Fabrication approved: no

8-pole speakON engineering boundary original orientation schematic
Original pinout diagram; read the exact variant and view below. Not to scale.

Orientation

How to read this profile

No V37 terminal-number sequence is published from the inspected public product-page evidence.

Source-scoped identification facts

Each value retains its exact example, role and measurement axis. Facts from different parts must not be combined into an invented component.

Documented examples; not a mating drawing or compatibility approval
Nominal contacts8S211Nominal pole count only; V36 does not assign amplifier channels or terminals.
Connector rolecable socket (NL8FC)S916Named source examples retain separate role, part, view and axis limits; values are not a universal family specification. NL8FC. Documented role: cable socket. Current8–20mm cableODacceptance is not external connector diameter. Not an ACmains/power-supply connector.
Mountingcable (Claim C208A); cable (Claim C208B)S211 · S211Recorded source-scoped values; named examples do not describe every family variant or establish compatibility. V36 catalogue-expansion identification fact only; not independent technical approval, fabrication data, wiring instruction or end-to-end compatibility proof. Exact component role and retention. No amplifier channel allocation, bridge-mode wiring, cable rating or power-supply use is established.
Coupling / latchlatch (Claim C208B); Quick Lock twist-latch (NL8FC)S211 · S916Named source examples retain separate role, part, view and axis limits; values are not a universal family specification. Exact component role and retention. No amplifier channel allocation, bridge-mode wiring, cable rating or power-supply use is established. NL8FC. Documented role: cable socket. Current8–20mm cableODacceptance is not external connector diameter. Not an ACmains/power-supply connector.
ManufacturerNeutrik (NL8FC)S916Named source examples retain separate role, part, view and axis limits; values are not a universal family specification. NL8FC. Documented role: cable socket. Current8–20mm cableODacceptance is not external connector diameter. Not an ACmains/power-supply connector.
SeriesspeakON (NL8FC)S916Named source examples retain separate role, part, view and axis limits; values are not a universal family specification. NL8FC. Documented role: cable socket. Current8–20mm cableODacceptance is not external connector diameter. Not an ACmains/power-supply connector.
Exact part / implementationNL8FC (NL8FC)S916Named source examples retain separate role, part, view and axis limits; values are not a universal family specification. NL8FC. Documented role: cable socket. Current8–20mm cableODacceptance is not external connector diameter. Not an ACmains/power-supply connector.

Not recorded: Positions / cavity span, Populated contacts, Contact rows, Contact pitch, Dimensions / axis, Contact gender / arrangement, Keying / polarization, Shell / form, Recorded markings, View convention. Unknown fields stay unknown; illustrations supply no measurements or pin assignments.

Recorded variant and source limits
  • Pole count does not establish amplifier-channel assignment.
  • The connector family is not an AC mains connector.
  • No fabrication dimensions or live-connection procedure are published.
  • Neutrik 8-pole speakON contact designations (NL8MPR chassis, NL8FC cable): Neutrik designations; BDA 458 NL8MPR drawing and BDA 456 NL8FC wiring drawing.
  • Neutrik wiring suggestion: 4-way system on one NL8MPR socket: Neutrik designations.
  • Neutrik NL8MPR contact designations (no application): Neutrik contact designations 1+ ... 4-; BDA 458 shows the NL8MPR from the rear (tab) side. Do not transfer positions to the mating face.
  • d&b D20 Touring rack '4 CH OUTPUTS' NL8 (all four D20 channels): Neutrik contact designations 1+ ... 4-; BDA 458 shows the NL8MPR from the rear (tab) side. Do not transfer positions to the mating face.
  • Neutrik wiring suggestion: 4-way system on one NL8 cable: Neutrik contact designations 1+ ... 4-; BDA 458 shows the NL8MPR from the rear (tab) side. Do not transfer positions to the mating face.
Report a correction to these facts →

Pins & wiring

Pinout

Choose the exact wiring. Pin numbers follow its stated view; a schematic does not establish physical positions. Check your exact device before wiring.

What the status labels mean
Confirmed
Recorded research passes agree within this variant; this is not independent human review or hardware validation.
Single source
Only one underlying document, or one pass, supports this assignment.
Device-specific
Supported for the named equipment or wiring only. Check your device’s manual.
Unverified
Missing or conflicting evidence. Do not wire from this row.
Not connected
The source explicitly says NC, no contact or no pin for this wiring.
Wiring variant

Neutrik 8-pole speakON contact designations (NL8MPR chassis, NL8FC cable)

View and evidence limits

Neutrik designations; BDA 458 NL8MPR drawing and BDA 456 NL8FC wiring drawing.

  • P208 speakON 8-pole — **Agree** on contact names and Neutrik's 4-way suggestion (1 LF, 2 low-mid, 3 high-mid, 4 HF) — B adds d&b D20 (contacts 1–4 = channels A–D).
  • No amplifier or loudspeaker manual using an 8-pole speakON was retrieved; amplifier channel mapping is not established.
8-pole speakON engineering boundaryNeutrik designations; BDA 458 NL8MPR drawing and BDA 456 NL8FC wiring drawing.SCHEMATIC · physical positions unconfirmedNot to scale · check the named wiring and device manual1+: 1+ (single_source)1+1-: 1- (single_source)1-2+: 2+ (single_source)2+2-: 2- (single_source)2-3+: 3+ (single_source)3+3-: 3- (single_source)3-4+: 4+ (single_source)4+4-: 4- (single_source)4-powergrounddataConfigshieldNCUnknown
Schematic only · physical contact positions unconfirmed. Original drawing · not to scale. Scroll sideways if needed.
Neutrik 8-pole speakON contact designations (NL8MPR chassis, NL8FC cable) — source-scoped contact map
PinSignalWhat it doesStatus
1+1+Control, detection or configuration connection; check the source and device.Single source
Sources
1-1-Control, detection or configuration connection; check the source and device.Single source
Sources
2+2+Control, detection or configuration connection; check the source and device.Single source
Sources
2-2-Control, detection or configuration connection; check the source and device.Single source
Sources
3+3+Control, detection or configuration connection; check the source and device.Single source
Sources
3-3-Control, detection or configuration connection; check the source and device.Single source
Sources
4+4+Control, detection or configuration connection; check the source and device.Single source
Sources
4-4-Control, detection or configuration connection; check the source and device.Single source
Sources
Sources (2)

Neutrik wiring suggestion: 4-way system on one NL8MPR socket

View and evidence limits

Neutrik designations.

  • P208 speakON 8-pole — **Agree** on contact names and Neutrik's 4-way suggestion (1 LF, 2 low-mid, 3 high-mid, 4 HF) — B adds d&b D20 (contacts 1–4 = channels A–D).
  • Application suggestion by Neutrik.
  • No amplifier or loudspeaker manual using an 8-pole speakON was retrieved; amplifier channel mapping is not established.
8-pole speakON engineering boundaryNeutrik designations.SCHEMATIC · physical positions unconfirmedNot to scale · check the named wiring and device manual1+: Low frequency + (single_source)1+1-: Low frequency - (single_source)1-2+: Low-mid frequency + (single_source)2+2-: Low-mid frequency - (single_source)2-3+: High-mid frequency + (single_source)3+3-: High-mid frequency - (single_source)3-4+: High frequency + (single_source)4+4-: High frequency - (single_source)4-powergrounddataConfigshieldNCUnknown
Schematic only · physical contact positions unconfirmed. Original drawing · not to scale. Scroll sideways if needed.
Neutrik wiring suggestion: 4-way system on one NL8MPR socket — source-scoped contact map
PinSignalWhat it doesStatus
1+Low frequency +Control, detection or configuration connection; check the source and device.Single source
Sources
1-Low frequency -Control, detection or configuration connection; check the source and device.Single source
Sources
2+Low-mid frequency +Control, detection or configuration connection; check the source and device.Single source
Sources
2-Low-mid frequency -Control, detection or configuration connection; check the source and device.Single source
Sources
3+High-mid frequency +Control, detection or configuration connection; check the source and device.Single source
Sources
3-High-mid frequency -Control, detection or configuration connection; check the source and device.Single source
Sources
4+High frequency +Control, detection or configuration connection; check the source and device.Single source
Sources
4-High frequency -Control, detection or configuration connection; check the source and device.Single source
Sources
Sources (1)

Neutrik NL8MPR contact designations (no application)

View and evidence limits

Neutrik contact designations 1+ ... 4-; BDA 458 shows the NL8MPR from the rear (tab) side. Do not transfer positions to the mating face.

  • P208 speakON 8-pole — **Agree** on contact names and Neutrik's 4-way suggestion (1 LF, 2 low-mid, 3 high-mid, 4 HF) — B adds d&b D20 (contacts 1–4 = channels A–D).
  • Only the d&b D20 rack and Neutrik's own suggestion were established; other manufacturers' NL8 channel or band orders are unverified.
8-pole speakON engineering boundaryNeutrik contact designations 1+ ... 4-; BDA 458 shows the NL8MPR from the rear (tab) side. Do not transfer positions to the mating face.SCHEMATIC · physical positions unconfirmedNot to scale · check the named wiring and device manual1+: 1+ (single_source)1+1-: 1- (single_source)1-2+: 2+ (single_source)2+2-: 2- (single_source)2-3+: 3+ (single_source)3+3-: 3- (single_source)3-4+: 4+ (single_source)4+4-: 4- (single_source)4-powergrounddataConfigshieldNCUnknown
Schematic only · physical contact positions unconfirmed. Original drawing · not to scale. Scroll sideways if needed.
Neutrik NL8MPR contact designations (no application) — source-scoped contact map
PinSignalWhat it doesStatus
1+1+Control, detection or configuration connection; check the source and device.Single source
Sources
1-1-Control, detection or configuration connection; check the source and device.Single source
Sources
2+2+Control, detection or configuration connection; check the source and device.Single source
Sources
2-2-Control, detection or configuration connection; check the source and device.Single source
Sources
3+3+Control, detection or configuration connection; check the source and device.Single source
Sources
3-3-Control, detection or configuration connection; check the source and device.Single source
Sources
4+4+Control, detection or configuration connection; check the source and device.Single source
Sources
4-4-Control, detection or configuration connection; check the source and device.Single source
Sources
Sources (1)

d&b D20 Touring rack '4 CH OUTPUTS' NL8 (all four D20 channels)

View and evidence limits

Neutrik contact designations 1+ ... 4-; BDA 458 shows the NL8MPR from the rear (tab) side. Do not transfer positions to the mating face.

  • P208 speakON 8-pole — **Agree** on contact names and Neutrik's 4-way suggestion (1 LF, 2 low-mid, 3 high-mid, 4 HF) — B adds d&b D20 (contacts 1–4 = channels A–D).
  • d&b states these connectors are only for rack panels, multicores (Z5343) and breakouts (Z5347/Z4348), never for direct loudspeaker connection.
  • Only the d&b D20 rack and Neutrik's own suggestion were established; other manufacturers' NL8 channel or band orders are unverified.
8-pole speakON engineering boundaryNeutrik contact designations 1+ ... 4-; BDA 458 shows the NL8MPR from the rear (tab) side. Do not transfer positions to the mating face.SCHEMATIC · physical positions unconfirmedNot to scale · check the named wiring and device manual1+: Channel A pos. (single_source)1+1-: Channel A neg. (single_source)1-2+: Channel B pos. (single_source)2+2-: Channel B neg. (single_source)2-3+: Channel C pos. (single_source)3+3-: Channel C neg. (single_source)3-4+: Channel D pos. (single_source)4+4-: Channel D neg. (single_source)4-powergrounddataConfigshieldNCUnknown
Schematic only · physical contact positions unconfirmed. Original drawing · not to scale. Scroll sideways if needed.
d&b D20 Touring rack '4 CH OUTPUTS' NL8 (all four D20 channels) — source-scoped contact map
PinSignalWhat it doesStatus
1+Channel A pos.Control, detection or configuration connection; check the source and device.Single source
Sources
1-Channel A neg.Control, detection or configuration connection; check the source and device.Single source
Sources
2+Channel B pos.Control, detection or configuration connection; check the source and device.Single source
Sources
2-Channel B neg.Control, detection or configuration connection; check the source and device.Single source
Sources
3+Channel C pos.Control, detection or configuration connection; check the source and device.Single source
Sources
3-Channel C neg.Control, detection or configuration connection; check the source and device.Single source
Sources
4+Channel D pos.Control, detection or configuration connection; check the source and device.Single source
Sources
4-Channel D neg.Control, detection or configuration connection; check the source and device.Single source
Sources
Sources (1)

Neutrik wiring suggestion: 4-way system on one NL8 cable

View and evidence limits

Neutrik contact designations 1+ ... 4-; BDA 458 shows the NL8MPR from the rear (tab) side. Do not transfer positions to the mating face.

  • P208 speakON 8-pole — **Agree** on contact names and Neutrik's 4-way suggestion (1 LF, 2 low-mid, 3 high-mid, 4 HF) — B adds d&b D20 (contacts 1–4 = channels A–D).
  • Only the d&b D20 rack and Neutrik's own suggestion were established; other manufacturers' NL8 channel or band orders are unverified.
8-pole speakON engineering boundaryNeutrik contact designations 1+ ... 4-; BDA 458 shows the NL8MPR from the rear (tab) side. Do not transfer positions to the mating face.SCHEMATIC · physical positions unconfirmedNot to scale · check the named wiring and device manual1+: low frequency + (single_source)1+1-: low frequency - (single_source)1-2+: low mid frequency + (single_source)2+2-: low mid frequency - (single_source)2-3+: high mid frequency + (single_source)3+3-: high mid frequency - (single_source)3-4+: high frequency + (single_source)4+4-: high frequency - (single_source)4-powergrounddataConfigshieldNCUnknown
Schematic only · physical contact positions unconfirmed. Original drawing · not to scale. Scroll sideways if needed.
Neutrik wiring suggestion: 4-way system on one NL8 cable — source-scoped contact map
PinSignalWhat it doesStatus
1+low frequency +Control, detection or configuration connection; check the source and device.Single source
Sources
1-low frequency -Control, detection or configuration connection; check the source and device.Single source
Sources
2+low mid frequency +Control, detection or configuration connection; check the source and device.Single source
Sources
2-low mid frequency -Control, detection or configuration connection; check the source and device.Single source
Sources
3+high mid frequency +Control, detection or configuration connection; check the source and device.Single source
Sources
3-high mid frequency -Control, detection or configuration connection; check the source and device.Single source
Sources
4+high frequency +Control, detection or configuration connection; check the source and device.Single source
Sources
4-high frequency -Control, detection or configuration connection; check the source and device.Single source
Sources
Sources (1)

Unknowns stay unknown.

  • Pole count does not establish amplifier-channel assignment.
  • The connector family is not an AC mains connector.
  • No fabrication dimensions or live-connection procedure are published.

Your next step

Use the detail without guessing past its limits.

Source trail

Claims and sources

C208Asource checked

Neutrik identifies NL8FC as an eight-pole speakON cable connector and excludes the connector family from AC mains use.

Neutrik · NL8FC 8-pole speakON cable connector ↗
Product overview and application warning · Identification/reference scope only. V36 does not convert this source into a universal pinout, fabrication drawing, electrical approval or end-to-end compatibility verdict.

C807Ssource checked

Neutrik 8-pole speakON contact designations (NL8MPR chassis, NL8FC cable): original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Neutrik · Assembly Instruction speakON Chassis Connector NL2MP & NL4MP & NL8MPR (BDA 458) ↗
p. 1, NL2MP / NL4MP / NL8MPR 'WIRING' drawings (contact legends) · Source scope and unresolved evidence are preserved in the engineering variant.

Neutrik · Assembly Instruction speakON NL8FC Lockable Loudspeaker Connector (BDA 456) ↗
p. 1, 'WIRING' drawing (contact legends 1+ to 4-) · Source scope and unresolved evidence are preserved in the engineering variant.

C807Tsource checked

Neutrik wiring suggestion: 4-way system on one NL8MPR socket: original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Neutrik · Product Guide, Section 03 speakON (EN) ↗
p. 16, 'speakON Wiring' - 'Wiring Suggestion' panel (polarity note and per-application pin use) · Source scope and unresolved evidence are preserved in the engineering variant.

C807Usource checked

Neutrik NL8MPR contact designations (no application): original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Neutrik · Assembly Instruction, speakON Chassis Connector NL2MP & NL4MP & NL8MPR ↗
p. 1, NL2MP section, 'WIRING' drawing (rear/tab side) labelled 1+ and 1-; p. 1, NL4MP section, 'WIRING' drawing labelled 1+, 1-, 2+, 2-; p. 1, NL8MPR section, 'WIRING' drawing labelled 1+ through 4- · Source scope and unresolved evidence are preserved in the engineering variant.

C807Vsource checked

d&b D20 Touring rack '4 CH OUTPUTS' NL8 (all four D20 channels): original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

d&b audiotechnik · D20 Touring rack assembly US Manual ↗
p. 8, section 3.3.1 '4 CH. OUTPUTS - NL8' pin assignment list · Source scope and unresolved evidence are preserved in the engineering variant.

C807Wsource checked

Neutrik wiring suggestion: 4-way system on one NL8 cable: original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Neutrik · speakON Wiring - Wiring Suggestion (catalogue page 71) ↗
p. 1 (catalogue p. 71), legend: '"+" = In phase (high) "-" = Ground (out of phase, low)'; p. 1 (catalogue p. 71), table row '4 Way System'; p. 1 (catalogue p. 71), table row 'Bi-Amp' and 'Bi-Amp' drawing · Source scope and unresolved evidence are preserved in the engineering variant.

7 source records support this profile. No independent engineering review or hardware validation is claimed.

Evidence behind this page

Scope first. Source second. Approval separate.

7 linked sources · 6 scoped claims · 0 sources with inspection/access flags.

Page scope: No V37 engineering drawing published; count/identifier evidence only.

Assessment 2026-10-22 · earliest scheduled source review 2027-01-03. This is a recorded-date assessment, not a live source check. Page-level independent review is not established by this panel.

Inspect 7 source scopes, access limits and dates

S211 · NL8FC 8-pole speakON cable connector

Neutrik · Manufacturer / product-owner domain · inspected 2026-10-05 · due 2027-01-03

Within inspection window

Scoped support: Identifies NL8FC as an eight-pole speakON cable connector and distinguishes the loudspeaker connector family from AC mains use.

Not established / limitations: Identification/reference scope only. V36 does not convert this source into a universal pinout, fabrication drawing, electrical approval or end-to-end compatibility verdict.

Locator: Product overview and application warning

S749 · Assembly Instruction speakON Chassis Connector NL2MP & NL4MP & NL8MPR (BDA 458)

Neutrik · Manufacturer / product-owner domain · inspected 2026-10-21 · due 2027-01-19

Within inspection window

Scoped support: Exact named pinout variant only; not capability or compatibility approval.

Not established / limitations: Source scope and unresolved evidence are preserved in the engineering variant.

Locator: p. 1, NL2MP / NL4MP / NL8MPR 'WIRING' drawings (contact legends)

S751 · Product Guide, Section 03 speakON (EN)

Neutrik · Manufacturer / product-owner domain · inspected 2026-10-21 · due 2027-01-19

Within inspection window

Scoped support: Exact named pinout variant only; not capability or compatibility approval.

Not established / limitations: Source scope and unresolved evidence are preserved in the engineering variant.

Locator: p. 16, 'speakON Wiring' - 'Wiring Suggestion' panel (polarity note and per-application pin use)

S752 · Assembly Instruction, speakON Chassis Connector NL2MP & NL4MP & NL8MPR

Neutrik · Manufacturer / product-owner domain · inspected 2026-10-20 · due 2027-01-18

Within inspection window

Scoped support: Exact named pinout variant only; not capability or compatibility approval.

Not established / limitations: Source scope and unresolved evidence are preserved in the engineering variant.

Locator: p. 1, NL2MP section, 'WIRING' drawing (rear/tab side) labelled 1+ and 1-; p. 1, NL4MP section, 'WIRING' drawing labelled 1+, 1-, 2+, 2-; p. 1, NL8MPR section, 'WIRING' drawing labelled 1+ through 4-

S753 · speakON Wiring - Wiring Suggestion (catalogue page 71)

Neutrik · Manufacturer / product-owner domain · inspected 2026-10-20 · due 2027-01-18

Within inspection window

Scoped support: Exact named pinout variant only; not capability or compatibility approval.

Not established / limitations: Source scope and unresolved evidence are preserved in the engineering variant.

Locator: p. 1 (catalogue p. 71), legend: '"+" = In phase (high) "-" = Ground (out of phase, low)'; p. 1 (catalogue p. 71), table row '4 Way System'; p. 1 (catalogue p. 71), table row 'Bi-Amp' and 'Bi-Amp' drawing

S790 · Assembly Instruction speakON NL8FC Lockable Loudspeaker Connector (BDA 456)

Neutrik · Manufacturer / product-owner domain · inspected 2026-10-21 · due 2027-01-19

Within inspection window

Scoped support: Exact named pinout variant only; not capability or compatibility approval.

Not established / limitations: Source scope and unresolved evidence are preserved in the engineering variant.

Locator: p. 1, 'WIRING' drawing (contact legends 1+ to 4-)

S791 · D20 Touring rack assembly US Manual

d&b audiotechnik · Unclassified publisher domain · inspected 2026-10-21 · due 2027-01-19

Within inspection window

Scoped support: Exact named pinout variant only; not capability or compatibility approval.

Not established / limitations: Source scope and unresolved evidence are preserved in the engineering variant.

Locator: p. 8, section 3.3.1 '4 CH. OUTPUTS - NL8' pin assignment list

Trace 6 claims to their source records

C208A · P208

Neutrik identifies NL8FC as an eight-pole speakON cable connector and excludes the connector family from AC mains use.

Claim scope: V36 catalogue-expansion identification fact only; not independent technical approval, fabrication data, wiring instruction or end-to-end compatibility proof.

Source links: S211 · Evidence trail → (private workspace)

C807S · P208

Neutrik 8-pole speakON contact designations (NL8MPR chassis, NL8FC cable): original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Claim scope: Pinout variant only; see comparison and per-contact status. Not fabrication approval.

Source links: S749 · S790 · Evidence trail → (private workspace)

C807T · P208

Neutrik wiring suggestion: 4-way system on one NL8MPR socket: original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Claim scope: Pinout variant only; see comparison and per-contact status. Not fabrication approval.

Source links: S751 · Evidence trail → (private workspace)

C807U · P208

Neutrik NL8MPR contact designations (no application): original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Claim scope: Pinout variant only; see comparison and per-contact status. Not fabrication approval.

Source links: S752 · Evidence trail → (private workspace)

C807V · P208

d&b D20 Touring rack '4 CH OUTPUTS' NL8 (all four D20 channels): original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Claim scope: Pinout variant only; see comparison and per-contact status. Not fabrication approval.

Source links: S791 · Evidence trail → (private workspace)

C807W · P208

Neutrik wiring suggestion: 4-way system on one NL8 cable: original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Claim scope: Pinout variant only; see comparison and per-contact status. Not fabrication approval.

Source links: S753 · Evidence trail → (private workspace)

Prepare this page for review → (private workspace)Read the evidence method →

Recorded evidence only. An inspection date, publisher label, source link or generated packet is not independent technical review, hardware testing, fabrication approval or a compatibility verdict.