Molex 0743232031 documents 23 loaded circuits in a digital/analog single-link component. Single-link population is kept separate from a full dual-link receptacle. This page publishes count-only evidence, not an invented single-link pin map.

Source checked · no independent review claimed · Fabrication approved: no

DVI-I single-link connector — scoped DVI reference original orientation schematic
Original pinout diagram; read the exact variant and view below. Not to scale.

Orientation

How to read this profile

Count the small-contact grid separately from the blade and any surrounding analog contacts. No numbered mating-face, solder-side or PCB assignment is published for this single-link profile.

Source-scoped identification facts

Each value retains its exact example, role and measurement axis. Facts from different parts must not be combined into an invented component.

Documented examples; not a mating drawing or compatibility approval
Nominal contacts23S093Source naming counts the blade in the 23-pin total; do not treat the drawing as a pinout.
Positions / cavity span23 (Claim C116C)S415Recorded source-scoped values; named examples do not describe every family variant or establish compatibility. Exact archived component example; not a measured universal connector dimension or electrical capability of an unknown device.
Connector rolesocket (DIS-23PFFP-SL8001)S933Named source examples retain separate role, part, view and axis limits; values are not a universal family specification. DIS-23PFFP-SL8001. Documented role: socket. Manufacturer malformed4inch-40UNC text denotes its published nut-thread vocabulary; no thread dimension derived.; No pitch,contact-row count or outer dimensions transferred from a DVI-I dual-link part.; CatalogPDF access403; exact lineup page successfully read. Cable variants have different -20to80C range; not mixed with receptacle.
Coupling / latchScrew thread retention; front-fastened PCB180degree receptacle; manufacturer labels4inch-40UNC nut thread (DIS-23PFFP-SL8001)S933Named source examples retain separate role, part, view and axis limits; values are not a universal family specification. DIS-23PFFP-SL8001. Documented role: socket. Manufacturer malformed4inch-40UNC text denotes its published nut-thread vocabulary; no thread dimension derived.; No pitch,contact-row count or outer dimensions transferred from a DVI-I dual-link part.; CatalogPDF access403; exact lineup page successfully read. Cable variants have different -20to80C range; not mixed with receptacle.
ManufacturerAmphenol LTW (DIS-23PFFP-SL8001)S933Named source examples retain separate role, part, view and axis limits; values are not a universal family specification. DIS-23PFFP-SL8001. Documented role: socket. Manufacturer malformed4inch-40UNC text denotes its published nut-thread vocabulary; no thread dimension derived.; No pitch,contact-row count or outer dimensions transferred from a DVI-I dual-link part.; CatalogPDF access403; exact lineup page successfully read. Cable variants have different -20to80C range; not mixed with receptacle.
SeriesDIS DVI-I single (DIS-23PFFP-SL8001)S933Named source examples retain separate role, part, view and axis limits; values are not a universal family specification. DIS-23PFFP-SL8001. Documented role: socket. Manufacturer malformed4inch-40UNC text denotes its published nut-thread vocabulary; no thread dimension derived.; No pitch,contact-row count or outer dimensions transferred from a DVI-I dual-link part.; CatalogPDF access403; exact lineup page successfully read. Cable variants have different -20to80C range; not mixed with receptacle.
Exact part / implementationDIS-23PFFP-SL8001 (DIS-23PFFP-SL8001)S933Named source examples retain separate role, part, view and axis limits; values are not a universal family specification. DIS-23PFFP-SL8001. Documented role: socket. Manufacturer malformed4inch-40UNC text denotes its published nut-thread vocabulary; no thread dimension derived.; No pitch,contact-row count or outer dimensions transferred from a DVI-I dual-link part.; CatalogPDF access403; exact lineup page successfully read. Cable variants have different -20to80C range; not mixed with receptacle.

Not recorded: Populated contacts, Contact rows, Contact pitch, Dimensions / axis, Contact gender / arrangement, Mounting, Keying / polarization, Shell / form, Recorded markings, View convention. Unknown fields stay unknown; illustrations supply no measurements or pin assignments.

Recorded variant and source limits
  • The flat digital blade is not an invented numbered signal 25. Different vendor counts can include or exclude it.
  • No housing dimensions, tolerances, insertion depth, PCB layout or fabrication approval is established.
  • Full receptacle contact presence is not evidence that a source, cable or receiver operates both links.
  • Do not apply voltage or modify connector pins based on a reference table. Exact device wiring and operating requirements remain separate.
  • DVI 1.0 combined connector (Table 5-2) used for single-link operation: Receptacle mating face, pin 1 upper left (Figure 5-3).
  • Kontron ADD2-DVI-Dual card DVI-I output, digital-only single link (device-specific): Manufacturer 'Front view' sketch: pin 1 upper left, 8 upper right of array, 24 lower right; C1/C2 top, C3/C4 bottom, C5 centre.
  • DDWG DVI 1.0 combined connector (Table 5-2), used single-link: Receptacle face per DDWG Fig. 5-3 (p. 46); numbering by contact number.
  • Prior view context (not a source-view value): Count the small-contact grid separately from the blade and any surrounding analog contacts. No numbered mating-face, solder-side or PCB assignment is published for this single-link profile.
Report a correction to these facts →

Pins & wiring

Pinout

Choose the exact wiring. Pin numbers follow its stated view; a schematic does not establish physical positions. Check your exact device before wiring.

What the status labels mean
Confirmed
Recorded research passes agree within this variant; this is not independent human review or hardware validation.
Single source
Only one underlying document, or one pass, supports this assignment.
Device-specific
Supported for the named equipment or wiring only. Check your device’s manual.
Unverified
Missing or conflicting evidence. Do not wire from this row.
Not connected
The source explicitly says NC, no contact or no pin for this wiring.
Wiring variant

DVI 1.0 combined connector (Table 5-2) used for single-link operation

View and evidence limits

Receptacle mating face, pin 1 upper left (Figure 5-3).

  • P116 DVI-I single-link — **Agree** on DVI 1.0 Table 5-2 — Same single-link caveat as P013. A adds the Kontron ADD2 output, a digital-only device variant with C1–C5 not connected.
  • DVI 1.0 defines no separate single-link DVI-I contact set; link #1 positions are recorded as unverified.
  • As for P013: DVI 1.0 is silent on whether pins 4, 5, 12, 13, 20, 21 are populated or wired on single-link DVI-I hardware.
  • No named manufacturer document was found that shows a single-link DVI-I port with active analog C1-C5 and N.C. second-link positions. The only device-specific variant found (Kontron) leaves the analog contacts unconnected.
DVI-I single-link connector — scoped DVI referenceReceptacle mating face, pin 1 upper left (Figure 5-3).SCHEMATIC · physical positions unconfirmedNot to scale · check the named wiring and device manual1: T.M.D.S. Data2- (single_source)12: T.M.D.S. Data2+ (single_source)23: T.M.D.S. Data2/4 Shield (single_source)34: Not confirmed (unverified)45: Not confirmed (unverified)56: DDC Clock (single_source)67: DDC Data (single_source)78: Analog Vertical Sync (single_source)89: T.M.D.S. Data1- (single_source)910: T.M.D.S. Data1+ (single_source)1011: T.M.D.S. Data1/3 Shield (single_source)1112: Not confirmed (unverified)1213: Not confirmed (unverified)1314: +5V Power (single_source)1415: Ground (return for +5V, HSync, and VSync) (single_source)1516: Hot Plug Detect (single_source)1617: T.M.D.S. Data0- (single_source)1718: T.M.D.S. Data0+ (single_source)1819: T.M.D.S. Data0/5 Shield (single_source)1920: Not confirmed (unverified)2021: Not confirmed (unverified)2122: T.M.D.S. Clock Shield (single_source)2223: T.M.D.S. Clock+ (single_source)2324: T.M.D.S. Clock- (single_source)24C1: Analog Red (single_source)C1C2: Analog Green (single_source)C2C3: Analog Blue (single_source)C3C4: Analog Horizontal Sync (single_source)C4C5: Analog Ground (single_source)C5powergrounddataConfigshieldNCUnknown
Schematic only · physical contact positions unconfirmed. Original drawing · not to scale. Scroll sideways if needed.
DVI 1.0 combined connector (Table 5-2) used for single-link operation — source-scoped contact map
PinSignalWhat it doesStatus
1T.M.D.S. Data2-Signal conductor. Pair, polarity and direction follow this named wiring.Single source
Sources
2T.M.D.S. Data2+Signal conductor. Pair, polarity and direction follow this named wiring.Single source
Sources
3T.M.D.S. Data2/4 ShieldCable screen or shield connection; check the named equipment.Single source
Sources
4Not confirmedNo settled assignment. Do not wire from this row.Unverified
Sources
5Not confirmedNo settled assignment. Do not wire from this row.Unverified
Sources
6DDC ClockClock or clock-control connection, as named by this source.Single source
Sources
7DDC DataSignal conductor. Pair, polarity and direction follow this named wiring.Single source
Sources
8Analog Vertical SyncControl, detection or configuration connection; check the source and device.Single source
Sources
9T.M.D.S. Data1-Signal conductor. Pair, polarity and direction follow this named wiring.Single source
Sources
10T.M.D.S. Data1+Signal conductor. Pair, polarity and direction follow this named wiring.Single source
Sources
11T.M.D.S. Data1/3 ShieldCable screen or shield connection; check the named equipment.Single source
Sources
12Not confirmedNo settled assignment. Do not wire from this row.Unverified
Sources
13Not confirmedNo settled assignment. Do not wire from this row.Unverified
Sources
14+5V PowerPower connection (+5V Power). Check the specified supply.Single source
Sources
15Ground (return for +5V, HSync, and VSync)Ground reference and return.Single source
Sources
16Hot Plug DetectControl, detection or configuration connection; check the source and device.Single source
Sources
17T.M.D.S. Data0-Signal conductor. Pair, polarity and direction follow this named wiring.Single source
Sources
18T.M.D.S. Data0+Signal conductor. Pair, polarity and direction follow this named wiring.Single source
Sources
19T.M.D.S. Data0/5 ShieldCable screen or shield connection; check the named equipment.Single source
Sources
20Not confirmedNo settled assignment. Do not wire from this row.Unverified
Sources
21Not confirmedNo settled assignment. Do not wire from this row.Unverified
Sources
22T.M.D.S. Clock ShieldCable screen or shield connection; check the named equipment.Single source
Sources
23T.M.D.S. Clock+Clock or clock-control connection, as named by this source.Single source
Sources
24T.M.D.S. Clock-Clock or clock-control connection, as named by this source.Single source
Sources
C1Analog RedControl, detection or configuration connection; check the source and device.Single source
Sources
C2Analog GreenWire colour for this termination: Analog Green.Single source
Sources
C3Analog BlueWire colour for this termination: Analog Blue.Single source
Sources
C4Analog Horizontal SyncControl, detection or configuration connection; check the source and device.Single source
Sources
C5Analog GroundControl, detection or configuration connection; check the source and device.Single source
Sources

Kontron ADD2-DVI-Dual card DVI-I output, digital-only single link (device-specific)

Device-specific wiring. Check your device’s manual before connecting or applying power.

View and evidence limits

Manufacturer 'Front view' sketch: pin 1 upper left, 8 upper right of array, 24 lower right; C1/C2 top, C3/C4 bottom, C5 centre.

  • P116 DVI-I single-link — **Agree** on DVI 1.0 Table 5-2 — Same single-link caveat as P013. A adds the Kontron ADD2 output, a digital-only device variant with C1–C5 not connected.
  • Device-specific: a DVI-I receptacle (Molex 74320-1004 or similar) wired for single-link digital only; C1-C5, pin 8 and second-link positions are N.C.
  • As for P013: DVI 1.0 is silent on whether pins 4, 5, 12, 13, 20, 21 are populated or wired on single-link DVI-I hardware.
  • No named manufacturer document was found that shows a single-link DVI-I port with active analog C1-C5 and N.C. second-link positions. The only device-specific variant found (Kontron) leaves the analog contacts unconnected.
DVI-I single-link connector — scoped DVI referenceManufacturer 'Front view' sketch: pin 1 upper left, 8 upper right of array, 24 lower right; C1/C2 top, C3/C4 bottom, C5 centre.SCHEMATIC · physical positions unconfirmedNot to scale · check the named wiring and device manual1: TMDS Data 2- (device_specific)12: TMDS Data 2+ (device_specific)23: TMDS Data 2/4 Shield (device_specific)34: N.C. (not_connected)45: N.C. (not_connected)56: DDC Clock (device_specific)67: DDC Data (device_specific)78: N.C. (not_connected)89: TMDS Data 1- (device_specific)910: TMDS Data 1+ (device_specific)1011: TMDS Data 1/3 Shield (device_specific)1112: N.C. (not_connected)1213: N.C. (not_connected)1314: +5V (55mA) (device_specific)1415: GND (device_specific)1516: Hot Plug Detect (device_specific)1617: TMDS Data 0- (device_specific)1718: TMDS Data 0+ (device_specific)1819: TMDS Data 0/5 Shield (device_specific)1920: N.C. (not_connected)2021: N.C. (not_connected)2122: TMDS Clock Shield (device_specific)2223: TMDS Clock+ (device_specific)2324: TMDS Clock- (device_specific)24C1: N.C. (not_connected)C1C2: N.C. (not_connected)C2C3: N.C. (not_connected)C3C4: N.C. (not_connected)C4C5: N.C. (not_connected)C5powergrounddataConfigshieldNCUnknown
Schematic only · physical contact positions unconfirmed. Original drawing · not to scale. Scroll sideways if needed.
Kontron ADD2-DVI-Dual card DVI-I output, digital-only single link (device-specific) — source-scoped contact map
PinSignalWhat it doesStatus
1TMDS Data 2-Signal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
2TMDS Data 2+Signal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
3TMDS Data 2/4 ShieldCable screen or shield connection; check the named equipment.Device-specific
Sources
4N.C.Explicitly not connected in this named manufacturer implementation. Do not wire this contact.Not connected
Sources
5N.C.Explicitly not connected in this named manufacturer implementation. Do not wire this contact.Not connected
Sources
6DDC ClockClock or clock-control connection, as named by this source.Device-specific
Sources
7DDC DataSignal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
8N.C.Not connected or absent in this named wiring.Not connected
Sources
9TMDS Data 1-Signal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
10TMDS Data 1+Signal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
11TMDS Data 1/3 ShieldCable screen or shield connection; check the named equipment.Device-specific
Sources
12N.C.Explicitly not connected in this named manufacturer implementation. Do not wire this contact.Not connected
Sources
13N.C.Explicitly not connected in this named manufacturer implementation. Do not wire this contact.Not connected
Sources
14+5V (55mA)Power connection (+5V (55mA)). Check the specified supply.Device-specific
Sources
15GNDGround reference and return.Device-specific
Sources
16Hot Plug DetectControl, detection or configuration connection; check the source and device.Device-specific
Sources
17TMDS Data 0-Signal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
18TMDS Data 0+Signal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
19TMDS Data 0/5 ShieldCable screen or shield connection; check the named equipment.Device-specific
Sources
20N.C.Explicitly not connected in this named manufacturer implementation. Do not wire this contact.Not connected
Sources
21N.C.Explicitly not connected in this named manufacturer implementation. Do not wire this contact.Not connected
Sources
22TMDS Clock ShieldCable screen or shield connection; check the named equipment.Device-specific
Sources
23TMDS Clock+Clock or clock-control connection, as named by this source.Device-specific
Sources
24TMDS Clock-Clock or clock-control connection, as named by this source.Device-specific
Sources
C1N.C.Not connected or absent in this named wiring.Not connected
Sources
C2N.C.Not connected or absent in this named wiring.Not connected
Sources
C3N.C.Not connected or absent in this named wiring.Not connected
Sources
C4N.C.Not connected or absent in this named wiring.Not connected
Sources
C5N.C.Not connected or absent in this named wiring.Not connected
Sources
Sources (1)

DDWG DVI 1.0 combined connector (Table 5-2), used single-link

View and evidence limits

Receptacle face per DDWG Fig. 5-3 (p. 46); numbering by contact number.

  • P116 DVI-I single-link — **Agree** on DVI 1.0 Table 5-2 — Same single-link caveat as P013. A adds the Kontron ADD2 output, a digital-only device variant with C1–C5 not connected.
  • DVI 1.0 has no separate single-link DVI-I connector. The second-link pairs are inactive in single-link operation.
  • No manufacturer drawing or device manual was found that shows a single-link DVI-I connector or cable with contacts 4, 5, 12, 13, 20 and 21 omitted or unconnected. The two DVI-I device documents found (Apple Xserve, Euresys Picolo HD) both list the second-link pairs.
DVI-I single-link connector — scoped DVI referenceReceptacle face per DDWG Fig. 5-3 (p. 46); numbering by contact number.SCHEMATIC · physical positions unconfirmedNot to scale · check the named wiring and device manual1: T.M.D.S. Data2- (single_source)12: T.M.D.S. Data2+ (single_source)23: T.M.D.S. Data2/4 Shield (single_source)34: Not confirmed (unverified)45: Not confirmed (unverified)56: DDC Clock (single_source)67: DDC Data (single_source)78: Analog Vertical Sync (single_source)89: T.M.D.S. Data1- (single_source)910: T.M.D.S. Data1+ (single_source)1011: T.M.D.S. Data1/3 Shield (single_source)1112: Not confirmed (unverified)1213: Not confirmed (unverified)1314: +5V Power (single_source)1415: Ground (return for +5V, HSync and VSync) (single_source)1516: Hot Plug Detect (single_source)1617: T.M.D.S. Data0- (single_source)1718: T.M.D.S. Data0+ (single_source)1819: T.M.D.S. Data0/5 Shield (single_source)1920: Not confirmed (unverified)2021: Not confirmed (unverified)2122: T.M.D.S. Clock Shield (single_source)2223: T.M.D.S. Clock+ (single_source)2324: T.M.D.S. Clock- (single_source)24C1: Analog Red (single_source)C1C2: Analog Green (single_source)C2C3: Analog Blue (single_source)C3C4: Analog Horizontal Sync (single_source)C4C5: Analog Ground (single_source)C5powergrounddataConfigshieldNCUnknown
Schematic only · physical contact positions unconfirmed. Original drawing · not to scale. Scroll sideways if needed.
DDWG DVI 1.0 combined connector (Table 5-2), used single-link — source-scoped contact map
PinSignalWhat it doesStatus
1T.M.D.S. Data2-Signal conductor. Pair, polarity and direction follow this named wiring.Single source
Sources
2T.M.D.S. Data2+Signal conductor. Pair, polarity and direction follow this named wiring.Single source
Sources
3T.M.D.S. Data2/4 ShieldCable screen or shield connection; check the named equipment.Single source
Sources
4Not confirmedNo settled assignment. Do not wire from this row.Unverified
Sources
5Not confirmedNo settled assignment. Do not wire from this row.Unverified
Sources
6DDC ClockClock or clock-control connection, as named by this source.Single source
Sources
7DDC DataSignal conductor. Pair, polarity and direction follow this named wiring.Single source
Sources
8Analog Vertical SyncControl, detection or configuration connection; check the source and device.Single source
Sources
9T.M.D.S. Data1-Signal conductor. Pair, polarity and direction follow this named wiring.Single source
Sources
10T.M.D.S. Data1+Signal conductor. Pair, polarity and direction follow this named wiring.Single source
Sources
11T.M.D.S. Data1/3 ShieldCable screen or shield connection; check the named equipment.Single source
Sources
12Not confirmedNo settled assignment. Do not wire from this row.Unverified
Sources
13Not confirmedNo settled assignment. Do not wire from this row.Unverified
Sources
14+5V PowerPower connection (+5V Power). Check the specified supply.Single source
Sources
15Ground (return for +5V, HSync and VSync)Ground reference and return.Single source
Sources
16Hot Plug DetectControl, detection or configuration connection; check the source and device.Single source
Sources
17T.M.D.S. Data0-Signal conductor. Pair, polarity and direction follow this named wiring.Single source
Sources
18T.M.D.S. Data0+Signal conductor. Pair, polarity and direction follow this named wiring.Single source
Sources
19T.M.D.S. Data0/5 ShieldCable screen or shield connection; check the named equipment.Single source
Sources
20Not confirmedNo settled assignment. Do not wire from this row.Unverified
Sources
21Not confirmedNo settled assignment. Do not wire from this row.Unverified
Sources
22T.M.D.S. Clock ShieldCable screen or shield connection; check the named equipment.Single source
Sources
23T.M.D.S. Clock+Clock or clock-control connection, as named by this source.Single source
Sources
24T.M.D.S. Clock-Clock or clock-control connection, as named by this source.Single source
Sources
C1Analog RedControl, detection or configuration connection; check the source and device.Single source
Sources
C2Analog GreenWire colour for this termination: Analog Green.Single source
Sources
C3Analog BlueWire colour for this termination: Analog Blue.Single source
Sources
C4Analog Horizontal SyncControl, detection or configuration connection; check the source and device.Single source
Sources
C5Analog GroundControl, detection or configuration connection; check the source and device.Single source
Sources

Unknowns stay unknown.

  • The flat digital blade is not an invented numbered signal 25. Different vendor counts can include or exclude it.
  • No housing dimensions, tolerances, insertion depth, PCB layout or fabrication approval is established.
  • Full receptacle contact presence is not evidence that a source, cable or receiver operates both links.
  • Do not apply voltage or modify connector pins based on a reference table. Exact device wiring and operating requirements remain separate.

Your next step

Use the detail without guessing past its limits.

Source trail

Claims and sources

C116Csource checked

Molex’s 26 June 2015 sheet identifies 0743232031 as a digital/analog single-link DVI component with 23 circuits.

Molex · MicroCross DVI 0743232031 generated part sheet (26 June 2015) ↗
PDF p. 1: part number, digital/analog single-link description, 23 circuits. · Distributor-hosted primary manufacturer sheet. Not a current lifecycle statement, assembly drawing, universal mating tolerance or evidence of analog output from any chosen computer.

C116Dsource checked

Molex separately illustrates a digital/analog single-link cable family and notes that contact loading depends on the signal set. A single-link combined form is distinct from digital-only DVI and from a fully populated dual-link interface.

Molex · MicroCross DVI Connector System — signal interface and cable assemblies ↗
PDF p. 2: DVI-I Receptacle Connector Front View and signal roles; p. 3: single/dual-link and analog cable families; partially loaded plug note. · Archived brochure, not evidence of current availability. Plug contacts may be partially loaded for a signal set. Do not transfer full receptacle assignments to unspecified cables or PCB terminals.

C804Ysource checked

DVI 1.0 combined connector (Table 5-2) used for single-link operation: original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Digital Display Working Group (DDWG) · Digital Visual Interface (DVI) ↗
Section 2.6 Signal List (signal descriptions), p. 23 of 76; Section 5.2.1.1, Table 5-1 Digital-Only Connector Pin Assignments, p. 43 of 76; Section 5.2.1.2, Table 5-2 Combined Analog and Digital Connector Pin Assignments, p. 44 of 76; Section 5.2.6.1, Figure 5-6 Analog Plug Connector Mating Interface Dimensions, p. 47 of 76; Sections 2.2.2.1-2.2.2.2 T.M.D.S. Link System/Monitor Requirements, p. 13 of 76 · Source scope and unresolved evidence are preserved in the engineering variant. Recorded original location/access note: http://www.ddwg.org/lib/dvi_10.pdf (retrieved from Internet Archive capture https://web.archive.org/web/20060630104414/http://www.ddwg.org:80/lib/dvi_10.pdf; ddwg.org no longer serves it)

C804Zsource checked

Kontron ADD2-DVI-Dual card DVI-I output, digital-only single link (device-specific): original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Kontron · ADD2-DVI-Dual User Manual ↗
p. 8 of 9, Connector Description: DVI-I connector table (Pin No./Signal/Type/Pull Up) and 'Front view' sketch · Source scope and unresolved evidence are preserved in the engineering variant.

C805Asource checked

DDWG DVI 1.0 combined connector (Table 5-2), used single-link: original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Digital Display Working Group (DDWG) · Digital Visual Interface (DVI) ↗
Fig. 5-1 Digital-only Receptacle Connector Mating Interface Dimensions, p. 45 of 76; Sec. 2.2.2, Table 2-1 Single and Dual Link Operation and Sec. 2.2.2.1-2.2.2.2 link requirements, pp. 12-13 of 76; Sec. 2.6 Signal List (signal descriptions, link/channel mapping), p. 23 of 76; Sec. 5.2.1.1, Table 5-1 Digital-Only Connector Pin Assignments, p. 43 of 76; Sec. 5.2.1.2, Table 5-2 Combined Analog and Digital Connector Pin Assignments, p. 44 of 76; Sec. 5.2.6.1, Fig. 5-6 Analog Plug Connector Mating Interface Dimensions, p. 47 of 76 · Source scope and unresolved evidence are preserved in the engineering variant.

Digital Display Working Group (document hosted by Molex via TTI) · Digital Display Working Group Delivers DVI (summary sheet) ↗
p. 2, 'Combined Connector (with micro-cross)' pin/signal table; p. 2, 'Digital Only Connector' pin/signal table · Source scope and unresolved evidence are preserved in the engineering variant.

6 source records support this profile. No independent engineering review or hardware validation is claimed.

Evidence behind this page

Scope first. Source second. Approval separate.

6 linked sources · 5 scoped claims · 0 sources with inspection/access flags.

Page scope: No new drawing. Existing original unnumbered artwork remains an identification illustration, not the numbered source view.

Assessment 2026-10-22 · earliest scheduled source review 2027-01-05. This is a recorded-date assessment, not a live source check. Page-level independent review is not established by this panel.

Inspect 6 source scopes, access limits and dates

S412 · MicroCross DVI Connector System — signal interface and cable assemblies

Molex · Unclassified publisher domain · inspected 2026-10-07 · due 2027-01-05

Within inspection window

Scoped support: Primary manufacturer brochure hosted by Mouser. Numbered DVI-I front view and named cable-family distinctions.

Not established / limitations: Archived brochure, not evidence of current availability. Plug contacts may be partially loaded for a signal set. Do not transfer full receptacle assignments to unspecified cables or PCB terminals.

Locator: PDF p. 2: DVI-I Receptacle Connector Front View and signal roles; p. 3: single/dual-link and analog cable families; partially loaded plug note.

S415 · MicroCross DVI 0743232031 generated part sheet (26 June 2015)

Molex · Unclassified publisher domain · inspected 2026-10-07 · due 2027-01-05

Within inspection window

Scoped support: Exact archived digital/analog single-link component example with 23 circuits; corroborates the represented DVI-I single-link contact group.

Not established / limitations: Distributor-hosted primary manufacturer sheet. Not a current lifecycle statement, assembly drawing, universal mating tolerance or evidence of analog output from any chosen computer.

Locator: PDF p. 1: part number, digital/analog single-link description, 23 circuits.

S683 · Digital Visual Interface (DVI)

Digital Display Working Group (DDWG) · Unclassified publisher domain · inspected 2026-10-20 · due 2027-01-18

Within inspection window

Scoped support: Exact named pinout variant only; not capability or compatibility approval.

Not established / limitations: Source scope and unresolved evidence are preserved in the engineering variant. Recorded original location/access note: http://www.ddwg.org/lib/dvi_10.pdf (retrieved from Internet Archive capture https://web.archive.org/web/20060630104414/http://www.ddwg.org:80/lib/dvi_10.pdf; ddwg.org no longer serves it)

Locator: Section 2.6 Signal List (signal descriptions), p. 23 of 76; Section 5.2.1.1, Table 5-1 Digital-Only Connector Pin Assignments, p. 43 of 76; Section 5.2.1.2, Table 5-2 Combined Analog and Digital Connector Pin Assignments, p. 44 of 76; Section 5.2.6.1, Figure 5-6 Analog Plug Connector Mating Interface Dimensions, p. 47 of 76; Sections 2.2.2.1-2.2.2.2 T.M.D.S. Link System/Monitor Requirements, p. 13 of 76

S686 · Digital Visual Interface (DVI)

Digital Display Working Group (DDWG) · Unclassified publisher domain · inspected 2026-10-20 · due 2027-01-18

Within inspection window

Scoped support: Exact named pinout variant only; not capability or compatibility approval.

Not established / limitations: Source scope and unresolved evidence are preserved in the engineering variant.

Locator: Fig. 5-1 Digital-only Receptacle Connector Mating Interface Dimensions, p. 45 of 76; Sec. 2.2.2, Table 2-1 Single and Dual Link Operation and Sec. 2.2.2.1-2.2.2.2 link requirements, pp. 12-13 of 76; Sec. 2.6 Signal List (signal descriptions, link/channel mapping), p. 23 of 76; Sec. 5.2.1.1, Table 5-1 Digital-Only Connector Pin Assignments, p. 43 of 76; Sec. 5.2.1.2, Table 5-2 Combined Analog and Digital Connector Pin Assignments, p. 44 of 76; Sec. 5.2.6.1, Fig. 5-6 Analog Plug Connector Mating Interface Dimensions, p. 47 of 76

S687 · Digital Display Working Group Delivers DVI (summary sheet)

Digital Display Working Group (document hosted by Molex via TTI) · Unclassified publisher domain · inspected 2026-10-20 · due 2027-01-18

Within inspection window

Scoped support: Exact named pinout variant only; not capability or compatibility approval.

Not established / limitations: Source scope and unresolved evidence are preserved in the engineering variant.

Locator: p. 2, 'Combined Connector (with micro-cross)' pin/signal table; p. 2, 'Digital Only Connector' pin/signal table

S742 · ADD2-DVI-Dual User Manual

Kontron · Unclassified publisher domain · inspected 2026-10-20 · due 2027-01-18

Within inspection window

Scoped support: Exact named pinout variant only; not capability or compatibility approval.

Not established / limitations: Source scope and unresolved evidence are preserved in the engineering variant.

Locator: p. 8 of 9, Connector Description: DVI-I connector table (Pin No./Signal/Type/Pull Up) and 'Front view' sketch

Trace 5 claims to their source records

C116C · P116

Molex’s 26 June 2015 sheet identifies 0743232031 as a digital/analog single-link DVI component with 23 circuits.

Claim scope: Exact archived component example; not a measured universal connector dimension or electrical capability of an unknown device.

Source links: S415 · Evidence trail → (private workspace)

C116D · P116

Molex separately illustrates a digital/analog single-link cable family and notes that contact loading depends on the signal set. A single-link combined form is distinct from digital-only DVI and from a fully populated dual-link interface.

Claim scope: Cable-family distinction and partial-loading caveat; no inferred assembly pin mapping.

Source links: S412 · Evidence trail → (private workspace)

C804Y · P116

DVI 1.0 combined connector (Table 5-2) used for single-link operation: original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Claim scope: Pinout variant only; see comparison and per-contact status. Not fabrication approval.

Source links: S683 · Evidence trail → (private workspace)

C804Z · P116

Kontron ADD2-DVI-Dual card DVI-I output, digital-only single link (device-specific): original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Claim scope: Pinout variant only; see comparison and per-contact status. Not fabrication approval.

Source links: S742 · Evidence trail → (private workspace)

C805A · P116

DDWG DVI 1.0 combined connector (Table 5-2), used single-link: original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Claim scope: Pinout variant only; see comparison and per-contact status. Not fabrication approval.

Source links: S686 · S687 · Evidence trail → (private workspace)

Prepare this page for review → (private workspace)Read the evidence method →

Recorded evidence only. An inspection date, publisher label, source link or generated packet is not independent technical review, hardware testing, fabrication approval or a compatibility verdict.