FIELD GUIDESource-led reference

E018 · Source-scoped pinout variants

8P8C modular connector (commonly called RJ45) engineering reference

T568A/T568B termination convention, kept separate from Ethernet service, link rate, cable category and PoE capability.

Source checked · no independent review claimed · Fabrication approved: no

8P8C / T568A–T568B termination reference original orientation schematic
Original pinout diagram; read the exact variant and view below. Not to scale.

Orientation

How to read this profile

Front view of the jack, following the orientation described by the source. Contact numbers 1 through 8 are shown left-to-right in the V35 schematic.

Source-scoped identification facts

Each value retains its exact example, role and measurement axis. Facts from different parts must not be combined into an invented component.

Documented examples; not a mating drawing or compatibility approval
Nominal contacts8S020 · S021 · S1918-position modular jack termination reference; nominal engineering count, not automatically positions, population or a device wiring map. 8-position modular jack termination reference
Positions / cavity span8 (Claim C018A); 8 (Claim C018C); 8 (8P8C); 8 (6-569278-3 / MP-5EU-1)S020 · S191 · S869Separate exact examples; retain each value’s source, role, axis and part scope. Consumer identification / documented standard or product class only T568A/B pair-to-pin termination convention viewed from the front of the jack; not Ethernet-service, cable-category, link-rate or PoE proof Exact named example 6-569278-3 / MP-5EU-1: 8P8C modular plug kit. Exact example only; no universal geometry, electrical compatibility, fabrication approval or wiring instruction. Correction applies to this named plug example; preserve separate generic jack orientation and other role values. No T568 wiring map derived.
Populated contacts8 (8P8C convention); 8 (6-569278-3 / MP-5EU-1)S020 · S869Separate exact examples; retain each value’s source, role, axis and part scope. Consumer identification / documented standard or product class only Exact named example 6-569278-3 / MP-5EU-1: 8P8C modular plug kit. Exact example only; no universal geometry, electrical compatibility, fabrication approval or wiring instruction. Correction applies to this named plug example; preserve separate generic jack orientation and other role values. No T568 wiring map derived.
Contact pitch1.02 mm Manufacturer Pitch-Mating Interface (Molex 955012881 board jack)S982Current primary-source scoped values; named examples remain separate and unknowns are not inferred from illustrations. Exact Molex 95501-2881 right-angle 8P8C board jack; manufacturer mating-interface pitch only, separate from plug geometry or all modular parts.
Connector rolesocket; plug (6-569278-3 / MP-5EU-1)S020 · S021 · S191 · S869Separate exact examples; retain each value’s source, role, axis and part scope. 8-position modular jack termination reference Exact named example 6-569278-3 / MP-5EU-1: 8P8C modular plug kit. Exact example only; no universal geometry, electrical compatibility, fabrication approval or wiring instruction. Correction applies to this named plug example; preserve separate generic jack orientation and other role values. No T568 wiring map derived.
MountingIDC termination (6-569278-3 / MP-5EU-1)S869Separate exact examples; retain each value’s source, role, axis and part scope. Exact named example 6-569278-3 / MP-5EU-1: 8P8C modular plug kit. Exact example only; no universal geometry, electrical compatibility, fabrication approval or wiring instruction. Correction applies to this named plug example; preserve separate generic jack orientation and other role values. No T568 wiring map derived.
ManufacturerCommScope (6-569278-3 / MP-5EU-1)S612 · S613Recorded source-scoped values; named examples do not describe every family variant or establish compatibility. Named plug kit, not a completed lead, installed-port function, cable-category test or PoE verdict. No equivalence to similarly numbered TE parts is asserted.
Series8P8C modular (6-569278-3 / MP-5EU-1)S612 · S613Recorded source-scoped values; named examples do not describe every family variant or establish compatibility. Named plug kit, not a completed lead, installed-port function, cable-category test or PoE verdict. No equivalence to similarly numbered TE parts is asserted.
Exact part / implementation6-569278-3 / MP-5EU-1 (6-569278-3 / MP-5EU-1)S612 · S613Recorded source-scoped values; named examples do not describe every family variant or establish compatibility. Named plug kit, not a completed lead, installed-port function, cable-category test or PoE verdict. No equivalence to similarly numbered TE parts is asserted.
View conventionFront view of the jack, following the orientation described by the source. Contact numbers 1 through 8 are shown left-to-right in the V35 schematic.S020 · S021 · S191Recorded source-scoped values; named examples do not describe every family variant or establish compatibility. Existing engineering orientation text; source/part/view remains controlling.

Not recorded: Contact rows, Dimensions / axis, Contact gender / arrangement, Coupling / latch, Keying / polarization, Shell / form, Recorded markings. Unknown fields stay unknown; illustrations supply no measurements or pin assignments.

Recorded variant and source limits
  • V35 intentionally does not turn this termination map into proof of Ethernet, console, PoE or any specific link rate.
  • Mechanical modular-jack/plug tolerances are not published.
  • T568A: Receptacle contact numbers per Leviton Table 1. The manufacturer's figures show the rear/IDC termination side, analogous to a solder-side wiring view; they are not a consecutive left-to-right face diagram.
  • T568B: Receptacle contact numbers per Leviton Table 1. The manufacturer's figures show the rear/IDC termination side, analogous to a solder-side wiring view; they are not a consecutive left-to-right face diagram.
Report a correction to these facts →

Pins & wiring

Pinout

Choose the exact wiring. Pin numbers follow its stated view; a schematic does not establish physical positions. Check your exact device before wiring.

What the status labels mean
Confirmed
Recorded research passes agree within this variant; this is not independent human review or hardware validation.
Single source
Only one underlying document, or one pass, supports this assignment.
Device-specific
Supported for the named equipment or wiring only. Check your device’s manual.
Unverified
Missing or conflicting evidence. Do not wire from this row.
Not connected
The source explicitly says NC, no contact or no pin for this wiring.
Wiring variant

T568A

View and evidence limits

Receptacle contact numbers per Leviton Table 1. The manufacturer's figures show the rear/IDC termination side, analogous to a solder-side wiring view; they are not a consecutive left-to-right face diagram.

  • P018 8P8C (RJ45) — Agree on T568A and T568B colour order — TIA-568 paywalled; Panduit and others confirm. Ethernet pair naming differs by maker (wording only).
  • The Leviton sheet verifies contact numbers and rear termination locations, not a front-view left/right sequence. No face orientation is inferred from memory.
  • 10/100/1000BASE-T MDI/MDI-X, automatic crossover and PoE pin/voltage assignments require the appropriate PHY/PoE specification or exact equipment datasheet and are not independently tabulated here.
8P8C / T568A–T568B termination referenceReceptacle contact numbers per Leviton Table 1. The manufacturer's figures show the rear/IDC termination side, analogous to a solder-side wiring view; they are not a consecutive left-to-right face diagram.SCHEMATIC · physical positions unconfirmedNot to scale · check the named wiring and device manual1: White/Green (confirmed)12: Green (or Green/White) (confirmed)23: White/Orange (confirmed)34: Blue (or Blue/White) (confirmed)45: White/Blue (confirmed)56: Orange (or Orange/White) (confirmed)67: White/Brown (confirmed)78: Brown (or Brown/White) (confirmed)8powergrounddataConfigshieldNCUnknown
Schematic only · physical contact positions unconfirmed. Original drawing · not to scale. Scroll sideways if needed.
T568A — source-scoped contact map
PinSignalWhat it doesStatus
1White/GreenWire colour for this termination: White/Green.Confirmed
Sources
2Green (or Green/White)Wire colour for this termination: Green (or Green/White).Confirmed
Sources
3White/OrangeWire colour for this termination: White/Orange.Confirmed
Sources
4Blue (or Blue/White)Wire colour for this termination: Blue (or Blue/White).Confirmed
Sources
5White/BlueWire colour for this termination: White/Blue.Confirmed
Sources
6Orange (or Orange/White)Wire colour for this termination: Orange (or Orange/White).Confirmed
Sources
7White/BrownWire colour for this termination: White/Brown.Confirmed
Sources
8Brown (or Brown/White)Wire colour for this termination: Brown (or Brown/White).Confirmed
Sources
Sources (4)

T568B

View and evidence limits

Receptacle contact numbers per Leviton Table 1. The manufacturer's figures show the rear/IDC termination side, analogous to a solder-side wiring view; they are not a consecutive left-to-right face diagram.

  • P018 8P8C (RJ45) — Agree on T568A and T568B colour order — TIA-568 paywalled; Panduit and others confirm. Ethernet pair naming differs by maker (wording only).
  • The Leviton sheet verifies contact numbers and rear termination locations, not a front-view left/right sequence. No face orientation is inferred from memory.
  • 10/100/1000BASE-T MDI/MDI-X, automatic crossover and PoE pin/voltage assignments require the appropriate PHY/PoE specification or exact equipment datasheet and are not independently tabulated here.
8P8C / T568A–T568B termination referenceReceptacle contact numbers per Leviton Table 1. The manufacturer's figures show the rear/IDC termination side, analogous to a solder-side wiring view; they are not a consecutive left-to-right face diagram.SCHEMATIC · physical positions unconfirmedNot to scale · check the named wiring and device manual1: White/Orange (confirmed)12: Orange (or Orange/White) (confirmed)23: White/Green (confirmed)34: Blue (or Blue/White) (confirmed)45: White/Blue (confirmed)56: Green (or Green/White) (confirmed)67: White/Brown (confirmed)78: Brown (or Brown/White) (confirmed)8powergrounddataConfigshieldNCUnknown
Schematic only · physical contact positions unconfirmed. Original drawing · not to scale. Scroll sideways if needed.
T568B — source-scoped contact map
PinSignalWhat it doesStatus
1White/OrangeWire colour for this termination: White/Orange.Confirmed
Sources
2Orange (or Orange/White)Wire colour for this termination: Orange (or Orange/White).Confirmed
Sources
3White/GreenWire colour for this termination: White/Green.Confirmed
Sources
4Blue (or Blue/White)Wire colour for this termination: Blue (or Blue/White).Confirmed
Sources
5White/BlueWire colour for this termination: White/Blue.Confirmed
Sources
6Green (or Green/White)Wire colour for this termination: Green (or Green/White).Confirmed
Sources
7White/BrownWire colour for this termination: White/Brown.Confirmed
Sources
8Brown (or Brown/White)Wire colour for this termination: Brown (or Brown/White).Confirmed
Sources
Sources (4)

Unknowns stay unknown.

  • V35 intentionally does not turn this termination map into proof of Ethernet, console, PoE or any specific link rate.
  • Mechanical modular-jack/plug tolerances are not published.

Your next step

Use the detail without guessing past its limits.

Source trail

Claims and sources

C018Csource checked

T568A and T568B use the same eight-position modular termination but swap the green and orange pairs: T568A places green on pins 1–2 and orange on 3 and 6; T568B places orange on 1–2 and green on 3 and 6.

Fluke Networks · Differences Between Wiring Codes T568A vs T568B ↗
T568A versus T568B pair-to-pin differences and diagram orientation note · Termination convention only. It does not establish that an 8P8C-shaped port is Ethernet, its link rate, PoE support or cable-category performance.

C801Wsource checked

T568A: original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Leviton · EXTREME Cat 6 and Cat 5e QUICKPORT Jacks, Cat. Nos. 61110-XX6 / 5G110-XX5, Installation Instructions ↗
PDF p. 2, Table 1: T568A & T568B Wiring Standards / IDC Color Assignments; white-stripe note; Figures 2–3 · Source scope and unresolved evidence are preserved in the engineering variant.

Beckhoff Automation · BK9053 und BK9103 Buskoppler für PROFINET: Ethernet-Anschluss, 'Belegung des RJ45-Steckers' (German) ↗
'Belegung des RJ45-Steckers' table · Source scope and unresolved evidence are preserved in the engineering variant.

Schneider Electric · TMSES4 Wiring Diagram: RJ45 Connector Pin Assignment (EcoStruxure Machine Expert V2.2 hardware help) ↗
'Pin Assignment' table, columns 100BASE-T / 1000BASE-T (1000BASE-T); 'Pin Assignment' table, columns 100BASE-T / 1000BASE-T (100BASE-T) · Source scope and unresolved evidence are preserved in the engineering variant.

Beckhoff Automation · CP37xx-1600 Multi-touch Panel PC: Ethernet RJ45 (X102), 'Ethernet interface pin assignment' ↗
'Ethernet interface pin assignment' table (X102) · Source scope and unresolved evidence are preserved in the engineering variant.

C801Xsource checked

T568B: original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Leviton · EXTREME Cat 6 and Cat 5e QUICKPORT Jacks, Cat. Nos. 61110-XX6 / 5G110-XX5, Installation Instructions ↗
PDF p. 2, Table 1: T568A & T568B Wiring Standards / IDC Color Assignments; white-stripe note; Figures 2–3 · Source scope and unresolved evidence are preserved in the engineering variant.

Beckhoff Automation · BK9053 und BK9103 Buskoppler für PROFINET: Ethernet-Anschluss, 'Belegung des RJ45-Steckers' (German) ↗
'Belegung des RJ45-Steckers' table · Source scope and unresolved evidence are preserved in the engineering variant.

Schneider Electric · TMSES4 Wiring Diagram: RJ45 Connector Pin Assignment (EcoStruxure Machine Expert V2.2 hardware help) ↗
'Pin Assignment' table, columns 100BASE-T / 1000BASE-T (1000BASE-T); 'Pin Assignment' table, columns 100BASE-T / 1000BASE-T (100BASE-T) · Source scope and unresolved evidence are preserved in the engineering variant.

Beckhoff Automation · CP37xx-1600 Multi-touch Panel PC: Ethernet RJ45 (X102), 'Ethernet interface pin assignment' ↗
'Ethernet interface pin assignment' table (X102) · Source scope and unresolved evidence are preserved in the engineering variant.

C018Wsource checked

Molex identifies 95501-2881 as a right-angle 8P8C modular jack. Its chart separates 1.02 mm mating-interface pitch from 1.27 mm termination-interface pitch.

Molex · Molex 95501 modular-jack series chart, exact4/4,6/4,6/6,8/8 variants ↗
Full Export Spreadsheet table: exact955012441,955012641,955012661,955012881 rows. Web Description identifies modular JACK; Pitch-Mating Interface1.02 mm differs from Pitch-Termination Interface1.27 mm; Positions/Loaded Contacts4/4,6/4,6/6,8/8. · P111/P112 are plug records, so jack values are counterpart context only and excluded from their pitch numerator. Port Configuration1x1 is not contact-row count. No Number of Rows field or inspected face drawing on this chart.

8 source records support this profile. No independent engineering review or hardware validation is claimed.

Evidence behind this page

Scope first. Source second. Approval separate.

8 linked sources · 6 scoped claims · 0 sources with inspection/access flags.

Page scope: Original termination schematic; front-of-jack orientation explicit; not to scale.

Assessment 2026-10-22 · earliest scheduled source review 2026-12-30. This is a recorded-date assessment, not a live source check. Page-level independent review is not established by this panel.

Inspect 8 source scopes, access limits and dates

S020 · RJ45 connectors

TE Connectivity · Manufacturer / product-owner domain · inspected 2026-10-01 · due 2026-12-30

Within inspection window

Scoped support: 8P8C physical family; exact implementation remains product-specific.

Not established / limitations:

Locator: RJ45 / 8-position modular product family

S021 · USB to RJ45 FTDI console cable

Cable Matters · Manufacturer / product-owner domain · inspected 2026-10-01 · due 2026-12-30

Within inspection window

Scoped support: Scoped counterexample: an RJ45-shaped connection can be serial console rather than Ethernet.

Not established / limitations:

Locator: Console cable description

S191 · Differences Between Wiring Codes T568A vs T568B

Fluke Networks · Manufacturer / product-owner domain · inspected 2026-10-05 · due 2027-01-03

Within inspection window

Scoped support: Eight-position modular termination convention: green/orange pair swap between T568A and T568B, with diagrams described from the front of the jack.

Not established / limitations: Termination convention only. It does not establish that an 8P8C-shaped port is Ethernet, its link rate, PoE support or cable-category performance.

Locator: T568A versus T568B pair-to-pin differences and diagram orientation note

S694 · EXTREME Cat 6 and Cat 5e QUICKPORT Jacks, Cat. Nos. 61110-XX6 / 5G110-XX5, Installation Instructions

Leviton · Manufacturer / product-owner domain · inspected 2026-10-18 · due 2027-01-16

Within inspection window

Scoped support: Exact named pinout variant only; not capability or compatibility approval.

Not established / limitations: Source scope and unresolved evidence are preserved in the engineering variant.

Locator: PDF p. 2, Table 1: T568A & T568B Wiring Standards / IDC Color Assignments; white-stripe note; Figures 2–3

S696 · TMSES4 Wiring Diagram: RJ45 Connector Pin Assignment (EcoStruxure Machine Expert V2.2 hardware help)

Schneider Electric · Unclassified publisher domain · inspected 2026-10-18 · due 2027-01-16

Within inspection window

Scoped support: Exact named pinout variant only; not capability or compatibility approval.

Not established / limitations: Source scope and unresolved evidence are preserved in the engineering variant.

Locator: 'Pin Assignment' table, columns 100BASE-T / 1000BASE-T (1000BASE-T); 'Pin Assignment' table, columns 100BASE-T / 1000BASE-T (100BASE-T)

S982 · Molex 95501 modular-jack series chart, exact4/4,6/4,6/6,8/8 variants

Molex · Manufacturer / product-owner domain · inspected 2026-10-22 · due 2027-01-20

Within inspection window

Scoped support: Exact named right-angle board-jack rows only; no plug-role geometry transfer.

Not established / limitations: P111/P112 are plug records, so jack values are counterpart context only and excluded from their pitch numerator. Port Configuration1x1 is not contact-row count. No Number of Rows field or inspected face drawing on this chart.

Locator: Full Export Spreadsheet table: exact955012441,955012641,955012661,955012881 rows. Web Description identifies modular JACK; Pitch-Mating Interface1.02 mm differs from Pitch-Termination Interface1.27 mm; Positions/Loaded Contacts4/4,6/4,6/6,8/8.

Trace 6 claims to their source records

C018A · P018

The common RJ45-style modular connector family has eight positions and eight contacts.

Claim scope: Consumer identification / documented standard or product class only

Source links: S020 · Evidence trail → (private workspace)

C018B · P018

A manufacturer’s RJ45 console cable is a concrete example of this shape being used for serial console, not Ethernet.

Claim scope: Narrowly stated supporting distinction; not an end-to-end device guarantee

Source links: S021 · Evidence trail → (private workspace)

C018C · P018

T568A and T568B use the same eight-position modular termination but swap the green and orange pairs: T568A places green on pins 1–2 and orange on 3 and 6; T568B places orange on 1–2 and green on 3 and 6.

Claim scope: T568A/B pair-to-pin termination convention viewed from the front of the jack; not Ethernet-service, cable-category, link-rate or PoE proof

Source links: S191 · Evidence trail → (private workspace)

C018W · P018

Molex identifies 95501-2881 as a right-angle 8P8C modular jack. Its chart separates 1.02 mm mating-interface pitch from 1.27 mm termination-interface pitch.

Claim scope: Exact Molex 95501-2881 right-angle 8P8C board jack; manufacturer mating-interface pitch only, separate from plug geometry or all modular parts.

Source links: S982 · Evidence trail → (private workspace)

C801W · P018

T568A: original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Claim scope: Pinout variant only; see comparison and per-contact status. Not fabrication approval.

Source links: S694 · S695 · S696 · S697 · Evidence trail → (private workspace)

C801X · P018

T568B: original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Claim scope: Pinout variant only; see comparison and per-contact status. Not fabrication approval.

Source links: S694 · S695 · S696 · S697 · Evidence trail → (private workspace)

Prepare this page for review → (private workspace)Read the evidence method →

Recorded evidence only. An inspection date, publisher label, source link or generated packet is not independent technical review, hardware testing, fabrication approval or a compatibility verdict.