FIELD GUIDESource-led reference

Audio · Exact Product Example

CORDIAL CPL5LL4 — four-pole speaker cable

Select a four-core four-pole speaker cable for a documented amplifier-to-passive-speaker path.

Neutrik four-pole speakON cable plugend A
Neutrik four-pole speakON cable plugend B
Bidirectionaldirection evidence
Passiveconversion

Endpoint map

Start with what is physically represented

Passive speaker cable; source and destination are the documented amplifier output and passive-speaker input. Disconnect load/power as the equipment procedure requires before mating.

Choose for the actual job

Select a four-core four-pole speaker cable for a documented amplifier-to-passive-speaker path.

ConstructionDocumented

CLS425 four-core bare-copper loudspeaker cable, PVC, with four-pole Neutrik speakON ends.

Evidence: C995A

Fallback / lower modesConditional

No automatic conversion from four-pole to two-pole, bridge mode or bi-amp assignments; match both equipment manuals.

Evidence: C995A

Environment and handlingConditional

The operating instructions list CPL_LL4 in their IP20 group. Do not use as a mains or power-supply connection; do not connect under load. Damaged cables require removal and qualified service.

Evidence: C995A

Worked selection example

For an amplifier and passive speaker documented to use the same four-pole assignment, select the 5m CPL5LL4 and verify the exact assignment and load in both manuals before connection.

Common confusion: Four shell poles, four cable cores and the equipment's assigned signal/power roles are separate facts. A speakON cable is not an AC mains connector.

Next check: Confirm exact speaker pole assignment, amplifier output/load and selected cable length; turn equipment off as its procedure requires before mating.

Source-documented example; no hardware test

Capability ledger

Six questions kept separate

DataDocumented

Four-pole/four-core speaker cable for power-amplifier and passive-speaker use; no line-level or digital protocol conversion.

Evidence: C995A

Power / chargingConditional

Match the amplifier load, assigned poles and operating conditions. A cable or connector current rating does not establish an arbitrary amplifier/speaker combination.

Evidence: C995A

VideoNot Applicable

No video transport represented.

ConversionPassive

Passive cable using CLS425, four bare-copper cores and PVC jacket; four-pole Neutrik speakON cable ends.

Evidence: C995A

Length / reachDocumented

CPL5LL4, item11002, is the listed 5m variant. Other family lengths are separate selections.

Evidence: C995A

Markings / certificationConditional

CPL5LL4 and the full four-pole LL4 designation identify this choice; CPL LL and CPL LL2 are different assignments.

Evidence: C995A

Explicit unknowns
  • No physical sample or speaker-system load/current test was performed.
  • Exact equipment-specific pole assignment remains an endpoint-manual requirement.

Source boundary

Why this profile says what it says

Back to first citation ↑
C995ASource checked · pending review

CORDIAL CPL5LL4 item11002 is the listed 5m four-pole Neutrik speakON speaker cable with four bare-copper cores, CLS425 bulk cable and PVC jacket. The operating instructions prohibit mains/power-supply use and connecting under load; equipment pole/load requirements remain separate.

Scope: CORDIAL CPL5LL4 exact 5m variant; operating instructions Version1.1/2024 · review due 2027-01-21

CORDIAL · CPL LL4 speaker cable product page

Four-pole Neutrik speakON ends, four copper cores, CLS425/PVC; exact5m variant.

Open source ↗

Product information, technical data and lengths: CPL5LL4,11002 · Four-pole Neutrik speakON ends, four copper cores, CLS425/PVC; exact5m variant.

CORDIAL · Speaker cable with speakON plug operating instructions

Professional speaker-cable safe handling. Do not use as mains cable or connect under load; no installation or modification procedure is granted.

Open source ↗

English printed pp.28–33: product list, safety, improper use, damage and maintenance · Professional speaker-cable safe handling. Do not use as mains cable or connect under load; no installation or modification procedure is granted.

Evidence behind this page

Scope first. Source second. Approval separate.

2 linked sources · 1 scoped claims · 0 sources with inspection/access flags.

Page scope: exact-product-example

Assessment 2026-10-23 · earliest scheduled source review 2027-01-21. This is a recorded-date assessment, not a live source check. Page-level independent review is not established by this panel.

Inspect 2 source scopes, access limits and dates

S1128 · CPL LL4 speaker cable product page

CORDIAL · Unclassified publisher domain · inspected 2026-10-23 · due 2027-01-21

Within inspection window

Scoped support: Four-pole Neutrik speakON ends, four copper cores, CLS425/PVC; exact5m variant.

Not established / limitations: Four-pole Neutrik speakON ends, four copper cores, CLS425/PVC; exact5m variant.

Locator: Product information, technical data and lengths: CPL5LL4,11002

S1129 · Speaker cable with speakON plug operating instructions

CORDIAL · Unclassified publisher domain · inspected 2026-10-23 · due 2027-01-21

Within inspection window

Scoped support: Professional speaker-cable safe handling. Do not use as mains cable or connect under load; no installation or modification procedure is granted.

Not established / limitations: Professional speaker-cable safe handling. Do not use as mains cable or connect under load; no installation or modification procedure is granted.

Locator: English printed pp.28–33: product list, safety, improper use, damage and maintenance

Trace 1 claims to their source records

C995A · P815

CORDIAL CPL5LL4 item11002 is the listed 5m four-pole Neutrik speakON speaker cable with four bare-copper cores, CLS425 bulk cable and PVC jacket. The operating instructions prohibit mains/power-supply use and connecting under load; equipment pole/load requirements remain separate.

Claim scope: CORDIAL CPL5LL4 exact 5m variant; operating instructions Version1.1/2024

Source links: S1128 · S1129 · Evidence trail →

Prepare this page for review →Read the evidence method →

Recorded evidence only. An inspection date, publisher label, source link or generated packet is not independent technical review, hardware testing, fabrication approval or a compatibility verdict.