FIELD GUIDESource-led reference

E127 · Source-scoped pinout variants

2-pole speakON loudspeaker connector engineering reference

Neutrik NL2FXX-W-* terminal designations only; never an AC/DC mains or power-supply connector.

Source checked · no independent review claimed · Fabrication approved: no

2-pole speakON terminal-designation reference original orientation schematic
Original pinout diagram; read the exact variant and view below. Not to scale.

Orientation

How to read this profile

Terminal labels only; no mating-face geometry is asserted in the V35 data model.

Source-scoped identification facts

Each value retains its exact example, role and measurement axis. Facts from different parts must not be combined into an invented component.

Documented examples; not a mating drawing or compatibility approval
Nominal contacts2S102Nominal contact count; some implementations may omit populated positions. It is not a wiring map.
Connector rolecable socket (NL2FXX-W-S)S917Named source examples retain separate role, part, view and axis limits; values are not a universal family specification. NL2FXX-W-S. Documented role: cable socket. Current product PDF differs from olderBDA63830Arating. Preserve old source record and contextualize dates.; Not for ACmains or power supply use; not for interrupting current. Acceptance diameter6–12mm is not connector width.
Mountingcable (Claim C127C)S102 · S194Recorded source-scoped values; named examples do not describe every family variant or establish compatibility. Terminal designations for the named speakON cable-connector family only; not an amplifier channel assignment or live-connection approval
Coupling / latchTwist lock; mechanically aligned insert/chuck/housing (NL2FXX-W-S)S917Named source examples retain separate role, part, view and axis limits; values are not a universal family specification. NL2FXX-W-S. Documented role: cable socket. Current product PDF differs from olderBDA63830Arating. Preserve old source record and contextualize dates.; Not for ACmains or power supply use; not for interrupting current. Acceptance diameter6–12mm is not connector width.
ManufacturerNeutrik (NL2FXX-W-S)S917Named source examples retain separate role, part, view and axis limits; values are not a universal family specification. NL2FXX-W-S. Documented role: cable socket. Current product PDF differs from olderBDA63830Arating. Preserve old source record and contextualize dates.; Not for ACmains or power supply use; not for interrupting current. Acceptance diameter6–12mm is not connector width.
SeriesspeakON 2-pole (NL2FXX-W-S)S917Named source examples retain separate role, part, view and axis limits; values are not a universal family specification. NL2FXX-W-S. Documented role: cable socket. Current product PDF differs from olderBDA63830Arating. Preserve old source record and contextualize dates.; Not for ACmains or power supply use; not for interrupting current. Acceptance diameter6–12mm is not connector width.
Exact part / implementationNL2FXX-W-S (NL2FXX-W-S)S917Named source examples retain separate role, part, view and axis limits; values are not a universal family specification. NL2FXX-W-S. Documented role: cable socket. Current product PDF differs from olderBDA63830Arating. Preserve old source record and contextualize dates.; Not for ACmains or power supply use; not for interrupting current. Acceptance diameter6–12mm is not connector width.

Not recorded: Positions / cavity span, Populated contacts, Contact rows, Contact pitch, Dimensions / axis, Contact gender / arrangement, Keying / polarization, Shell / form, Recorded markings, View convention. Unknown fields stay unknown; illustrations supply no measurements or pin assignments.

Recorded variant and source limits
  • Amplifier channel assignment, polarity convention outside the named product documentation and system wiring remain device-specific.
  • Generic mating dimensions are not published.
  • Neutrik 2-pole speakON contact designations (NL2MP chassis, NL2FXX cable): Contact designations as moulded/printed by Neutrik; BDA 458 shows the NL2MP from the mating side, BDA 638 shows the cable insert wiring side.
  • Neutrik NL2MP chassis connector contact designations: Neutrik contact designations 1+ and 1- as printed on the insert; BDA 458 shows the NL2MP from the rear (FASTON tab) side. Positions are not transferred to the mating face.
  • Prior view context (not a source-view value): Terminal labels only; no mating-face geometry is asserted in the V35 data model.
Report a correction to these facts →

Pins & wiring

Pinout

Choose the exact wiring. Pin numbers follow its stated view; a schematic does not establish physical positions. Check your exact device before wiring.

What the status labels mean
Confirmed
Recorded research passes agree within this variant; this is not independent human review or hardware validation.
Single source
Only one underlying document, or one pass, supports this assignment.
Device-specific
Supported for the named equipment or wiring only. Check your device’s manual.
Unverified
Missing or conflicting evidence. Do not wire from this row.
Not connected
The source explicitly says NC, no contact or no pin for this wiring.
Wiring variant

Neutrik 2-pole speakON contact designations (NL2MP chassis, NL2FXX cable)

View and evidence limits

Contact designations as moulded/printed by Neutrik; BDA 458 shows the NL2MP from the mating side, BDA 638 shows the cable insert wiring side.

  • P127 speakON 2-pole — **Agree** (contacts 1+ and 1−) — Neutrik only; no amplifier document found by either pass.
  • The designation identifies the contact only; what it carries is set by the equipment.
  • No amplifier or loudspeaker manual specifically using 2-pole speakON was retrieved.
  • Intermating behaviour (which receptacle contacts a 2-pole plug engages) was not established from a Neutrik document in this pass.
2-pole speakON terminal-designation referenceContact designations as moulded/printed by Neutrik; BDA 458 shows the NL2MP from the mating side, BDA 638 shows the cable insert wiring side.SCHEMATIC · physical positions unconfirmedNot to scale · check the named wiring and device manual1+: 1+ (single_source)1+1-: 1- (single_source)1-powergrounddataConfigshieldNCUnknown
Schematic only · physical contact positions unconfirmed. Original drawing · not to scale. Scroll sideways if needed.
Neutrik 2-pole speakON contact designations (NL2MP chassis, NL2FXX cable) — source-scoped contact map
PinSignalWhat it doesStatus
1+1+Control, detection or configuration connection; check the source and device.Single source
Sources
1-1-Control, detection or configuration connection; check the source and device.Single source
Sources
Sources (3)

Neutrik NL2MP chassis connector contact designations

View and evidence limits

Neutrik contact designations 1+ and 1- as printed on the insert; BDA 458 shows the NL2MP from the rear (FASTON tab) side. Positions are not transferred to the mating face.

  • P127 speakON 2-pole — **Agree** (contacts 1+ and 1−) — Neutrik only; no amplifier document found by either pass.
  • No amplifier or loudspeaker manual that uses an NL2 chassis connector and states its signal assignment was located in this pass; only Neutrik's contact designations and polarity legend are recorded.
  • Behaviour of NL2 plugs in NL4 sockets is not stated in the documents read.
2-pole speakON terminal-designation referenceNeutrik contact designations 1+ and 1- as printed on the insert; BDA 458 shows the NL2MP from the rear (FASTON tab) side. Positions are not transferred to the mating face.SCHEMATIC · physical positions unconfirmedNot to scale · check the named wiring and device manual1+: 1+ (single_source)1+1-: 1- (single_source)1-powergrounddataConfigshieldNCUnknown
Schematic only · physical contact positions unconfirmed. Original drawing · not to scale. Scroll sideways if needed.
Neutrik NL2MP chassis connector contact designations — source-scoped contact map
PinSignalWhat it doesStatus
1+1+Control, detection or configuration connection; check the source and device.Single source
Sources
1-1-Control, detection or configuration connection; check the source and device.Single source
Sources
Sources (2)

Unknowns stay unknown.

  • Amplifier channel assignment, polarity convention outside the named product documentation and system wiring remain device-specific.
  • Generic mating dimensions are not published.

Your next step

Use the detail without guessing past its limits.

Source trail

Claims and sources

C127Asource checked

Neutrik NL2FXX-W-S is a two-contact speakON connector.

Neutrik · NL2FXX-W-S two-pole speakON ↗
Product; Electrical / contact count; Attention · No current-rating recommendation, wiring instructions or powerCON interchangeability.

C127Bsource checked

Neutrik excludes AC mains and power-supply use and warns against interrupting current with this connector.

Neutrik · NL2FXX-W-S two-pole speakON ↗
Product; Electrical / contact count; Attention · No current-rating recommendation, wiring instructions or powerCON interchangeability.

C127Csource checked

Neutrik’s documented two-pole speakON cable-connector assembly identifies its two terminals as 1+ and 1−.

Neutrik · NL2FXX-W-S two-pole speakON ↗
Product; Electrical / contact count; Attention · No current-rating recommendation, wiring instructions or powerCON interchangeability.

Neutrik · speakON NL2FXX-W-* & NL4FXX-W-* assembly instruction ↗
Page 1; WIRING: 2 POLE and WIRING: 4 POLE · Terminal designation reference only. V35 does not turn the assembly sheet into a device-level channel assignment or live-connection approval.

C805Lsource checked

Neutrik 2-pole speakON contact designations (NL2MP chassis, NL2FXX cable): original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Neutrik · Assembly Instruction speakON Chassis Connector NL2MP & NL4MP & NL8MPR (BDA 458) ↗
p. 1, NL2MP / NL4MP / NL8MPR 'WIRING' drawings (contact legends) · Source scope and unresolved evidence are preserved in the engineering variant.

Neutrik · Assembly Instruction speakON Loudspeaker Cable Connector NL2FXX-W-* & NL4FXX-W-* (BDA 638) ↗
p. 1, 'WIRING: 2 POLE' and 'WIRING: 4 POLE' drawings · Source scope and unresolved evidence are preserved in the engineering variant.

Neutrik · Product Guide, Section 03 speakON (EN) ↗
p. 16, 'speakON Wiring' - 'Wiring Suggestion' panel (polarity note and per-application pin use) · Source scope and unresolved evidence are preserved in the engineering variant.

C805Msource checked

Neutrik NL2MP chassis connector contact designations: original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Neutrik · Assembly Instruction, speakON Chassis Connector NL2MP & NL4MP & NL8MPR ↗
p. 1, NL2MP section, 'WIRING' drawing (rear/tab side) labelled 1+ and 1-; p. 1, NL4MP section, 'WIRING' drawing labelled 1+, 1-, 2+, 2-; p. 1, NL8MPR section, 'WIRING' drawing labelled 1+ through 4- · Source scope and unresolved evidence are preserved in the engineering variant.

Neutrik · speakON Wiring - Wiring Suggestion (catalogue page 71) ↗
p. 1 (catalogue p. 71), legend: '"+" = In phase (high) "-" = Ground (out of phase, low)'; p. 1 (catalogue p. 71), table row '4 Way System'; p. 1 (catalogue p. 71), table row 'Bi-Amp' and 'Bi-Amp' drawing · Source scope and unresolved evidence are preserved in the engineering variant.

7 source records support this profile. No independent engineering review or hardware validation is claimed.

Evidence behind this page

Scope first. Source second. Approval separate.

7 linked sources · 5 scoped claims · 0 sources with inspection/access flags.

Page scope: No source geometry reproduced; terminal designations are presented as text only.

Assessment 2026-10-22 · earliest scheduled source review 2027-01-01. This is a recorded-date assessment, not a live source check. Page-level independent review is not established by this panel.

Inspect 7 source scopes, access limits and dates

S102 · NL2FXX-W-S two-pole speakON

Neutrik · Manufacturer / product-owner domain · inspected 2026-10-03 · due 2027-01-01

Within inspection window

Scoped support: Two-contact speakON loudspeaker connector; not for mains or power supply use; not for interrupting current.

Not established / limitations: No current-rating recommendation, wiring instructions or powerCON interchangeability.

Locator: Product; Electrical / contact count; Attention

S194 · speakON NL2FXX-W-* & NL4FXX-W-* assembly instruction

Neutrik · Manufacturer / product-owner domain · inspected 2026-10-05 · due 2027-01-03

Within inspection window

Scoped support: Terminal designations shown for the documented 2-pole and 4-pole cable connectors: 1+/1− and 1+/1−/2−/2+ respectively.

Not established / limitations: Terminal designation reference only. V35 does not turn the assembly sheet into a device-level channel assignment or live-connection approval.

Locator: Page 1; WIRING: 2 POLE and WIRING: 4 POLE

S749 · Assembly Instruction speakON Chassis Connector NL2MP & NL4MP & NL8MPR (BDA 458)

Neutrik · Manufacturer / product-owner domain · inspected 2026-10-21 · due 2027-01-19

Within inspection window

Scoped support: Exact named pinout variant only; not capability or compatibility approval.

Not established / limitations: Source scope and unresolved evidence are preserved in the engineering variant.

Locator: p. 1, NL2MP / NL4MP / NL8MPR 'WIRING' drawings (contact legends)

S751 · Product Guide, Section 03 speakON (EN)

Neutrik · Manufacturer / product-owner domain · inspected 2026-10-21 · due 2027-01-19

Within inspection window

Scoped support: Exact named pinout variant only; not capability or compatibility approval.

Not established / limitations: Source scope and unresolved evidence are preserved in the engineering variant.

Locator: p. 16, 'speakON Wiring' - 'Wiring Suggestion' panel (polarity note and per-application pin use)

S752 · Assembly Instruction, speakON Chassis Connector NL2MP & NL4MP & NL8MPR

Neutrik · Manufacturer / product-owner domain · inspected 2026-10-20 · due 2027-01-18

Within inspection window

Scoped support: Exact named pinout variant only; not capability or compatibility approval.

Not established / limitations: Source scope and unresolved evidence are preserved in the engineering variant.

Locator: p. 1, NL2MP section, 'WIRING' drawing (rear/tab side) labelled 1+ and 1-; p. 1, NL4MP section, 'WIRING' drawing labelled 1+, 1-, 2+, 2-; p. 1, NL8MPR section, 'WIRING' drawing labelled 1+ through 4-

S753 · speakON Wiring - Wiring Suggestion (catalogue page 71)

Neutrik · Manufacturer / product-owner domain · inspected 2026-10-20 · due 2027-01-18

Within inspection window

Scoped support: Exact named pinout variant only; not capability or compatibility approval.

Not established / limitations: Source scope and unresolved evidence are preserved in the engineering variant.

Locator: p. 1 (catalogue p. 71), legend: '"+" = In phase (high) "-" = Ground (out of phase, low)'; p. 1 (catalogue p. 71), table row '4 Way System'; p. 1 (catalogue p. 71), table row 'Bi-Amp' and 'Bi-Amp' drawing

Trace 5 claims to their source records

C127A · P127

Neutrik NL2FXX-W-S is a two-contact speakON connector.

Claim scope: Identification and explicitly scoped documentation only; not an end-to-end connection approval

Source links: S102 · Evidence trail → (private workspace)

C127B · P127

Neutrik excludes AC mains and power-supply use and warns against interrupting current with this connector.

Claim scope: Identification and explicitly scoped documentation only; not an end-to-end connection approval

Source links: S102 · Evidence trail → (private workspace)

C127C · P127

Neutrik’s documented two-pole speakON cable-connector assembly identifies its two terminals as 1+ and 1−.

Claim scope: Terminal designations for the named speakON cable-connector family only; not an amplifier channel assignment or live-connection approval

Source links: S102 · S194 · Evidence trail → (private workspace)

C805L · P127

Neutrik 2-pole speakON contact designations (NL2MP chassis, NL2FXX cable): original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Claim scope: Pinout variant only; see comparison and per-contact status. Not fabrication approval.

Source links: S749 · S750 · S751 · Evidence trail → (private workspace)

C805M · P127

Neutrik NL2MP chassis connector contact designations: original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Claim scope: Pinout variant only; see comparison and per-contact status. Not fabrication approval.

Source links: S752 · S753 · Evidence trail → (private workspace)

Prepare this page for review → (private workspace)Read the evidence method →

Recorded evidence only. An inspection date, publisher label, source link or generated packet is not independent technical review, hardware testing, fabrication approval or a compatibility verdict.