FIELD GUIDESource-led reference

E200 · Source-scoped pinout variants

SFP / SFP+ / SFP28 host connector form engineering reference

Example Molex SFP/SFP+ host connector geometry; module electrical pad assignment is not published by this profile.

Source checked · no independent review claimed · Fabrication approved: no

SFP-family host connector mechanical identifier original orientation schematic
Original pinout diagram; read the exact variant and view below. Not to scale.

Orientation

How to read this profile

Example product is a right-angle, two-row host receptacle. V37 does not publish module-side pad numbering or a universal face-view orientation.

Bounded dimensions

Only what the sources support

Source-scoped dimensions; not fabrication clearances
FieldValueScopeEvidence
Example mating-interface pitch0.8 mmexample component[C200B]

Source-scoped identification facts

Each value retains its exact example, role and measurement axis. Facts from different parts must not be combined into an invented component.

Documented examples; not a mating drawing or compatibility approval
Nominal contacts20S203Source-backed host-connector position count; module electrical assignments are outside V36.
Positions / cavity span20 (Claim C200A); 20 (Claim C200C)S203 · S507Recorded source-scoped values; named examples do not describe every family variant or establish compatibility. V36 catalogue-expansion identification fact only; not independent technical approval, fabrication data, wiring instruction or end-to-end compatibility proof. V121 named-product or explicitly scoped manufacturer distinction only; no wiring instruction, independent engineering approval or end-to-end compatibility guarantee.
Contact rows2 (Claim C200B); 2 (0744410010)S217 · S217Named source examples retain separate role, part, view and axis limits; values are not a universal family specification. Molex product 744410010 documents an SFP/SFP+ host receptacle with 20 loaded circuits, two rows, right-angle orientation and 0.80 mm mating-interface pitch. | V37 engineering-depth sidecar fact; source-checked but not independently human-approved, not a fabrication drawing, and not a safe-substitution or repair instruction. 0744410010. Documented role: socket. 20loaded contacts; exact right-angle SMT part. No shape-based throughput approval.
Contact pitch0.8 mm Example mating-interface pitch (Recorded example component); 0.8 mm mating interface (0744410010)S217 · S217Named source examples retain separate role, part, view and axis limits; values are not a universal family specification. example_component; SFP/SFP+/SFP28 host receptacle 0744410010. Documented role: socket. 20loaded contacts; exact right-angle SMT part. No shape-based throughput approval.
Connector rolesocket; socket (0744410010)S203 · S217 · S217Named source examples retain separate role, part, view and axis limits; values are not a universal family specification. SFP/SFP+/SFP28 host receptacle 0744410010. Documented role: socket. 20loaded contacts; exact right-angle SMT part. No shape-based throughput approval.
Keying / polarizationKeyed/polarized/locked to mating part; PCB locator and retention (0744410010)S217Named source examples retain separate role, part, view and axis limits; values are not a universal family specification. 0744410010. Documented role: socket. 20loaded contacts; exact right-angle SMT part. No shape-based throughput approval.
ManufacturerMolex (0744410010)S217Named source examples retain separate role, part, view and axis limits; values are not a universal family specification. 0744410010. Documented role: socket. 20loaded contacts; exact right-angle SMT part. No shape-based throughput approval.
Series74441 (0744410010)S217Named source examples retain separate role, part, view and axis limits; values are not a universal family specification. 0744410010. Documented role: socket. 20loaded contacts; exact right-angle SMT part. No shape-based throughput approval.
Exact part / implementation0744410010 (0744410010)S217Named source examples retain separate role, part, view and axis limits; values are not a universal family specification. 0744410010. Documented role: socket. 20loaded contacts; exact right-angle SMT part. No shape-based throughput approval.

Not recorded: Populated contacts, Dimensions / axis, Contact gender / arrangement, Mounting, Coupling / latch, Shell / form, Recorded markings, View convention. Unknown fields stay unknown; illustrations supply no measurements or pin assignments.

Recorded variant and source limits
  • The 0.80 mm pitch and two-row construction are example-component facts, not a universal fabrication envelope.
  • No SFP electrical pin map is published in this profile.
  • SFP-family module capability remains module- and host-specific.
  • Classic SFP gigabit datacom / INF-8074i: MSA Appendix B Figure 1 host-board connector-block view, same orientation as Appendix A Figure 4; ASIC left,bezel right.
  • SFP+ transceiver interface / SFF-8431: Figure 1 host PCB top view: host/insertion left,bezel right; right column 10 top to1 bottom,left11 top to20 bottom. Figure 2 module top/through-board views.
  • SFP28 SFF-8472-managed interface / SFF-8419: Figure 7-1 host PCB top view: host/insertion left,bezel right. Figure 7-2 bottom pads viewed from top through board; top pads viewed from top. Rate-select labels conflict.
  • Amphenol AQP-XPB4-XXX SFP28 AOC end: Numbered manufacturer table; source-verified host spatial layout is not imported from other products.
  • Broadcom AFBR-57E6APZ SFP for FDDI/Fast Ethernet: Figure 2 p. 2 is the module PCB connection diagram: top of board, with bottom of board as viewed through top of board. Contact functions transfer by number to the host; host footprint mirroring is not inferred.
  • Coherent FTLX8574D3BCL SFP+: Manufacturer host-board connector diagram p. 2 has arrows Towards Bezel and Towards ASIC. Numbered table p. 3 used; the p. 2 pin-9 signal conflict is unresolved.
  • Coherent FTLF8536P5xyL SFP28 single-rate 25GbE: p. 2 Diagram of Host Board Connector Block Pin Numbers and Names: host to left with module insertion direction; bezel to right. Do not transfer to a module-bottom view.
  • Coherent FTLF8536P5xyV SFP28 dual-rate 10/25GbE: p. 2 Diagram of Host Board Connector Block Pin Numbers and Names: host to left with module insertion direction; bezel to right. Do not transfer to a module-bottom view.
Report a correction to these facts →

Pins & wiring

Pinout

Choose the exact wiring. Pin numbers follow its stated view; a schematic does not establish physical positions. Check your exact device before wiring.

What the status labels mean
Confirmed
Recorded research passes agree within this variant; this is not independent human review or hardware validation.
Single source
Only one underlying document, or one pass, supports this assignment.
Device-specific
Supported for the named equipment or wiring only. Check your device’s manual.
Unverified
Missing or conflicting evidence. Do not wire from this row.
Not connected
The source explicitly says NC, no contact or no pin for this wiring.
Wiring variant

Classic SFP gigabit datacom / INF-8074i

View and evidence limits

MSA Appendix B Figure 1 host-board connector-block view, same orientation as Appendix A Figure 4; ASIC left,bezel right.

  • P200 SFP / SFP+ / SFP28 host — **Partial; internal source conflicts remain** — A: SFP MSA, SFF-8431, SFF-8419/SFF-8402 and Amphenol AOC. B: Broadcom SFP and Coherent SFP+/SFP28 module datasheets. Common supply, management and differential data contacts align. B's Fast Ethernet SFP does not implement the MSA's fault/rate-select functions on 2/7. Legacy SFP 9 is ground; SFP+ and dual-rate SFP28 use a rate-select role. B's single-rate SFP28 explicitly makes 7/9 NC. **A's SFF-8419 rev 2.0a conflicts internally on labels at 7/9; B's Coherent SFP+ datasheet conflicts internally at 9 (VeeR versus RS1).** Those rows stay unverified. Different documents; another module's map cannot resolve either source's contradiction.
  • Two label conflicts internal to SFF-8419 remain unresolved; both source labels retained.
  • SFP112/SFP224 CMIS, AS0/AS1, passive cables, arbitrary vendor-specific behavior and supported link capability are not established.
SFP-family host connector mechanical identifierMSA Appendix B Figure 1 host-board connector-block view, same orientation as Appendix A Figure 4; ASIC left,bezel right.SCHEMATIC · physical positions unconfirmedNot to scale · check the named wiring and device manual1: VeeT (single_source)12: TX Fault (single_source)23: TX Disable (single_source)34: MOD-DEF2 (single_source)45: MOD-DEF1 (single_source)56: MOD-DEF0 (single_source)67: Rate Select (single_source)78: LOS (single_source)89: VeeR (single_source)910: VeeR (single_source)1011: VeeR (single_source)1112: RD- (single_source)1213: RD+ (single_source)1314: VeeR (single_source)1415: VccR (single_source)1516: VccT (single_source)1617: VeeT (single_source)1718: TD+ (single_source)1819: TD- (single_source)1920: VeeT (single_source)20powergrounddataConfigshieldNCUnknown
Schematic only · physical contact positions unconfirmed. Original drawing · not to scale. Scroll sideways if needed.

Not yet independently confirmed. No settled pin table is available for this wiring.

Sources (1)

SFP+ transceiver interface / SFF-8431

View and evidence limits

Figure 1 host PCB top view: host/insertion left,bezel right; right column 10 top to1 bottom,left11 top to20 bottom. Figure 2 module top/through-board views.

  • P200 SFP / SFP+ / SFP28 host — **Partial; internal source conflicts remain** — A: SFP MSA, SFF-8431, SFF-8419/SFF-8402 and Amphenol AOC. B: Broadcom SFP and Coherent SFP+/SFP28 module datasheets. Common supply, management and differential data contacts align. B's Fast Ethernet SFP does not implement the MSA's fault/rate-select functions on 2/7. Legacy SFP 9 is ground; SFP+ and dual-rate SFP28 use a rate-select role. B's single-rate SFP28 explicitly makes 7/9 NC. **A's SFF-8419 rev 2.0a conflicts internally on labels at 7/9; B's Coherent SFP+ datasheet conflicts internally at 9 (VeeR versus RS1).** Those rows stay unverified. Different documents; another module's map cannot resolve either source's contradiction.
  • Two label conflicts internal to SFF-8419 remain unresolved; both source labels retained.
  • SFP112/SFP224 CMIS, AS0/AS1, passive cables, arbitrary vendor-specific behavior and supported link capability are not established.
SFP-family host connector mechanical identifierFigure 1 host PCB top view: host/insertion left,bezel right; right column 10 top to1 bottom,left11 top to20 bottom. Figure 2 module top/through-board views.SCHEMATIC · physical positions unconfirmedNot to scale · check the named wiring and device manual1: VeeT (single_source)12: Tx_Fault (single_source)23: Tx_Disable (single_source)34: SDA (single_source)45: SCL (single_source)56: Mod_ABS (single_source)67: RS0 (single_source)78: Rx_LOS (single_source)89: RS1 (single_source)910: VeeR (single_source)1011: VeeR (single_source)1112: RD- (single_source)1213: RD+ (single_source)1314: VeeR (single_source)1415: VccR (single_source)1516: VccT (single_source)1617: VeeT (single_source)1718: TD+ (single_source)1819: TD- (single_source)1920: VeeT (single_source)20powergrounddataConfigshieldNCUnknown
Schematic only · physical contact positions unconfirmed. Original drawing · not to scale. Scroll sideways if needed.

Not yet independently confirmed. No settled pin table is available for this wiring.

Sources (1)

SFP28 SFF-8472-managed interface / SFF-8419

View and evidence limits

Figure 7-1 host PCB top view: host/insertion left,bezel right. Figure 7-2 bottom pads viewed from top through board; top pads viewed from top. Rate-select labels conflict.

  • P200 SFP / SFP+ / SFP28 host — **Partial; internal source conflicts remain** — A: SFP MSA, SFF-8431, SFF-8419/SFF-8402 and Amphenol AOC. B: Broadcom SFP and Coherent SFP+/SFP28 module datasheets. Common supply, management and differential data contacts align. B's Fast Ethernet SFP does not implement the MSA's fault/rate-select functions on 2/7. Legacy SFP 9 is ground; SFP+ and dual-rate SFP28 use a rate-select role. B's single-rate SFP28 explicitly makes 7/9 NC. **A's SFF-8419 rev 2.0a conflicts internally on labels at 7/9; B's Coherent SFP+ datasheet conflicts internally at 9 (VeeR versus RS1).** Those rows stay unverified. Different documents; another module's map cannot resolve either source's contradiction.
  • Two label conflicts internal to SFF-8419 remain unresolved; both source labels retained.
  • SFP112/SFP224 CMIS, AS0/AS1, passive cables, arbitrary vendor-specific behavior and supported link capability are not established.
SFP-family host connector mechanical identifierFigure 7-1 host PCB top view: host/insertion left,bezel right. Figure 7-2 bottom pads viewed from top through board; top pads viewed from top. Rate-select labels conflict.SCHEMATIC · physical positions unconfirmedNot to scale · check the named wiring and device manual1: VeeT (single_source)12: Tx_Fault (single_source)23: Tx_Disable (single_source)34: SDA (single_source)45: SCL (single_source)56: Mod_ABS (single_source)67: Not confirmed (unverified)78: Rx_LOS (single_source)89: Not confirmed (unverified)910: VeeR (single_source)1011: VeeR (single_source)1112: RD- (single_source)1213: RD+ (single_source)1314: VeeR (single_source)1415: VccR (single_source)1516: VccT (single_source)1617: VeeT (single_source)1718: TD+ (single_source)1819: TD- (single_source)1920: VeeT (single_source)20powergrounddataConfigshieldNCUnknown
Schematic only · physical contact positions unconfirmed. Original drawing · not to scale. Scroll sideways if needed.

Not yet independently confirmed. No settled pin table is available for this wiring.

Sources (1)

Amphenol AQP-XPB4-XXX SFP28 AOC end

Device-specific wiring. Check your device’s manual before connecting or applying power.

View and evidence limits

Numbered manufacturer table; source-verified host spatial layout is not imported from other products.

  • P200 SFP / SFP+ / SFP28 host — **Partial; internal source conflicts remain** — A: SFP MSA, SFF-8431, SFF-8419/SFF-8402 and Amphenol AOC. B: Broadcom SFP and Coherent SFP+/SFP28 module datasheets. Common supply, management and differential data contacts align. B's Fast Ethernet SFP does not implement the MSA's fault/rate-select functions on 2/7. Legacy SFP 9 is ground; SFP+ and dual-rate SFP28 use a rate-select role. B's single-rate SFP28 explicitly makes 7/9 NC. **A's SFF-8419 rev 2.0a conflicts internally on labels at 7/9; B's Coherent SFP+ datasheet conflicts internally at 9 (VeeR versus RS1).** Those rows stay unverified. Different documents; another module's map cannot resolve either source's contradiction.
  • Two label conflicts internal to SFF-8419 remain unresolved; both source labels retained.
  • SFP112/SFP224 CMIS, AS0/AS1, passive cables, arbitrary vendor-specific behavior and supported link capability are not established.
SFP-family host connector mechanical identifierNumbered manufacturer table; source-verified host spatial layout is not imported from other products.SCHEMATIC · physical positions unconfirmedNot to scale · check the named wiring and device manual1: VeeT (device_specific)12: Tx_Fault (device_specific)23: Tx_Disable (device_specific)34: SDA (device_specific)45: SCL (device_specific)56: Mod_ABS (device_specific)67: RS0 (device_specific)78: Rx_LOS (device_specific)89: RS1 (device_specific)910: VeeR (device_specific)1011: VeeR (device_specific)1112: RD- (device_specific)1213: RD+ (device_specific)1314: VeeR (device_specific)1415: VccR (device_specific)1516: VccT (device_specific)1617: VeeT (device_specific)1718: TD+ (device_specific)1819: TD- (device_specific)1920: VeeT (device_specific)20powergrounddataConfigshieldNCUnknown
Schematic only · physical contact positions unconfirmed. Original drawing · not to scale. Scroll sideways if needed.
Amphenol AQP-XPB4-XXX SFP28 AOC end — source-scoped contact map
PinSignalWhat it doesStatus
1VeeTGround reference and return.Device-specific
Sources
2Tx_FaultSignal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
3Tx_DisableSignal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
4SDAControl, detection or configuration connection; check the source and device.Device-specific
Sources
5SCLControl, detection or configuration connection; check the source and device.Device-specific
Sources
6Mod_ABSControl, detection or configuration connection; check the source and device.Device-specific
Sources
7RS0Control, detection or configuration connection; check the source and device.Device-specific
Sources
8Rx_LOSSignal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
9RS1Control, detection or configuration connection; check the source and device.Device-specific
Sources
10VeeRGround reference and return.Device-specific
Sources
11VeeRGround reference and return.Device-specific
Sources
12RD-Signal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
13RD+Signal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
14VeeRGround reference and return.Device-specific
Sources
15VccRPower connection (VccR). Check the specified supply.Device-specific
Sources
16VccTPower connection (VccT). Check the specified supply.Device-specific
Sources
17VeeTGround reference and return.Device-specific
Sources
18TD+Signal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
19TD-Signal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
20VeeTGround reference and return.Device-specific
Sources
Sources (1)

Broadcom AFBR-57E6APZ SFP for FDDI/Fast Ethernet

Device-specific wiring. Check your device’s manual before connecting or applying power.

View and evidence limits

Figure 2 p. 2 is the module PCB connection diagram: top of board, with bottom of board as viewed through top of board. Contact functions transfer by number to the host; host footprint mirroring is not inferred.

  • P200 SFP / SFP+ / SFP28 host — **Partial; internal source conflicts remain** — A: SFP MSA, SFF-8431, SFF-8419/SFF-8402 and Amphenol AOC. B: Broadcom SFP and Coherent SFP+/SFP28 module datasheets. Common supply, management and differential data contacts align. B's Fast Ethernet SFP does not implement the MSA's fault/rate-select functions on 2/7. Legacy SFP 9 is ground; SFP+ and dual-rate SFP28 use a rate-select role. B's single-rate SFP28 explicitly makes 7/9 NC. **A's SFF-8419 rev 2.0a conflicts internally on labels at 7/9; B's Coherent SFP+ datasheet conflicts internally at 9 (VeeR versus RS1).** Those rows stay unverified. Different documents; another module's map cannot resolve either source's contradiction.
  • NU means not used, not proven physically unconnected. Pin 2 is explicitly held low by this module.
  • FTLX8574D3BCL PDF p. 2 labels pin 9 VeeR; p. 3 labels it RS1 and says no connection required. It is explicitly unverified rather than choosing one label. The p. 2 figure also prints 1 at the bottom position where the table has pin 10, so that spatial numbering is not used.
  • These are named optical module examples, not universal assignments for copper SFP, DAC, other rates, vendor modules or equipment PCB solder tails. Power ratings and compatibility are not generalized.
SFP-family host connector mechanical identifierFigure 2 p. 2 is the module PCB connection diagram: top of board, with bottom of board as viewed through top of board. Contact functions transfer by number to the host; host footprint mirroring is not inferred.SCHEMATIC · physical positions unconfirmedNot to scale · check the named wiring and device manual1: VEET (device_specific)12: NU (device_specific)23: Tx Disable (device_specific)34: MOD-DEF2 (device_specific)45: MOD-DEF1 (device_specific)56: MOD-DEF0 (device_specific)67: NU (device_specific)78: LOS (device_specific)89: VEER (device_specific)910: VEER (device_specific)1011: VEER (device_specific)1112: RD- (device_specific)1213: RD+ (device_specific)1314: VEER (device_specific)1415: VCCR (device_specific)1516: VCCT (device_specific)1617: VEET (device_specific)1718: TD+ (device_specific)1819: TD- (device_specific)1920: VEET (device_specific)20powergrounddataConfigshieldNCUnknown
Schematic only · physical contact positions unconfirmed. Original drawing · not to scale. Scroll sideways if needed.
Broadcom AFBR-57E6APZ SFP for FDDI/Fast Ethernet — source-scoped contact map
PinSignalWhat it doesStatus
1VEETGround reference and return.Device-specific
Sources
2NUControl, detection or configuration connection; check the source and device.Device-specific
Sources
3Tx DisableSignal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
4MOD-DEF2Signal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
5MOD-DEF1Signal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
6MOD-DEF0Signal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
7NUControl, detection or configuration connection; check the source and device.Device-specific
Sources
8LOSControl, detection or configuration connection; check the source and device.Device-specific
Sources
9VEERGround reference and return.Device-specific
Sources
10VEERGround reference and return.Device-specific
Sources
11VEERGround reference and return.Device-specific
Sources
12RD-Signal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
13RD+Signal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
14VEERGround reference and return.Device-specific
Sources
15VCCRPower connection (VCCR). Check the specified supply.Device-specific
Sources
16VCCTPower connection (VCCT). Check the specified supply.Device-specific
Sources
17VEETGround reference and return.Device-specific
Sources
18TD+Signal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
19TD-Signal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
20VEETGround reference and return.Device-specific
Sources
Sources (1)

Coherent FTLX8574D3BCL SFP+

Device-specific wiring. Check your device’s manual before connecting or applying power.

View and evidence limits

Manufacturer host-board connector diagram p. 2 has arrows Towards Bezel and Towards ASIC. Numbered table p. 3 used; the p. 2 pin-9 signal conflict is unresolved.

  • P200 SFP / SFP+ / SFP28 host — **Partial; internal source conflicts remain** — A: SFP MSA, SFF-8431, SFF-8419/SFF-8402 and Amphenol AOC. B: Broadcom SFP and Coherent SFP+/SFP28 module datasheets. Common supply, management and differential data contacts align. B's Fast Ethernet SFP does not implement the MSA's fault/rate-select functions on 2/7. Legacy SFP 9 is ground; SFP+ and dual-rate SFP28 use a rate-select role. B's single-rate SFP28 explicitly makes 7/9 NC. **A's SFF-8419 rev 2.0a conflicts internally on labels at 7/9; B's Coherent SFP+ datasheet conflicts internally at 9 (VeeR versus RS1).** Those rows stay unverified. Different documents; another module's map cannot resolve either source's contradiction.
  • FTLX8574D3BCL PDF p. 2 labels pin 9 VeeR; p. 3 labels it RS1 and says no connection required. It is explicitly unverified rather than choosing one label. The p. 2 figure also prints 1 at the bottom position where the table has pin 10, so that spatial numbering is not used.
  • These are named optical module examples, not universal assignments for copper SFP, DAC, other rates, vendor modules or equipment PCB solder tails. Power ratings and compatibility are not generalized.
SFP-family host connector mechanical identifierManufacturer host-board connector diagram p. 2 has arrows Towards Bezel and Towards ASIC. Numbered table p. 3 used; the p. 2 pin-9 signal conflict is unresolved.SCHEMATIC · physical positions unconfirmedNot to scale · check the named wiring and device manual1: VEET (device_specific)12: TFAULT (device_specific)23: TDIS (device_specific)34: SDA (device_specific)45: SCL (device_specific)56: MOD_ABS (device_specific)67: RS0 (device_specific)78: RX_LOS (device_specific)89: Not confirmed (unverified)910: VEER (device_specific)1011: VEER (device_specific)1112: RD- (device_specific)1213: RD+ (device_specific)1314: VEER (device_specific)1415: VCCR (device_specific)1516: VCCT (device_specific)1617: VEET (device_specific)1718: TD+ (device_specific)1819: TD- (device_specific)1920: VEET (device_specific)20powergrounddataConfigshieldNCUnknown
Schematic only · physical contact positions unconfirmed. Original drawing · not to scale. Scroll sideways if needed.
Coherent FTLX8574D3BCL SFP+ — source-scoped contact map
PinSignalWhat it doesStatus
1VEETGround reference and return.Device-specific
Sources
2TFAULTControl, detection or configuration connection; check the source and device.Device-specific
Sources
3TDISControl, detection or configuration connection; check the source and device.Device-specific
Sources
4SDAControl, detection or configuration connection; check the source and device.Device-specific
Sources
5SCLControl, detection or configuration connection; check the source and device.Device-specific
Sources
6MOD_ABSControl, detection or configuration connection; check the source and device.Device-specific
Sources
7RS0Control, detection or configuration connection; check the source and device.Device-specific
Sources
8RX_LOSSignal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
9Not confirmedNo settled assignment. Do not wire from this row.Unverified
Sources
10VEERGround reference and return.Device-specific
Sources
11VEERGround reference and return.Device-specific
Sources
12RD-Signal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
13RD+Signal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
14VEERGround reference and return.Device-specific
Sources
15VCCRPower connection (VCCR). Check the specified supply.Device-specific
Sources
16VCCTPower connection (VCCT). Check the specified supply.Device-specific
Sources
17VEETGround reference and return.Device-specific
Sources
18TD+Signal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
19TD-Signal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
20VEETGround reference and return.Device-specific
Sources
Sources (1)

Coherent FTLF8536P5xyL SFP28 single-rate 25GbE

Device-specific wiring. Check your device’s manual before connecting or applying power.

View and evidence limits

p. 2 Diagram of Host Board Connector Block Pin Numbers and Names: host to left with module insertion direction; bezel to right. Do not transfer to a module-bottom view.

  • P200 SFP / SFP+ / SFP28 host — **Partial; internal source conflicts remain** — A: SFP MSA, SFF-8431, SFF-8419/SFF-8402 and Amphenol AOC. B: Broadcom SFP and Coherent SFP+/SFP28 module datasheets. Common supply, management and differential data contacts align. B's Fast Ethernet SFP does not implement the MSA's fault/rate-select functions on 2/7. Legacy SFP 9 is ground; SFP+ and dual-rate SFP28 use a rate-select role. B's single-rate SFP28 explicitly makes 7/9 NC. **A's SFF-8419 rev 2.0a conflicts internally on labels at 7/9; B's Coherent SFP+ datasheet conflicts internally at 9 (VeeR versus RS1).** Those rows stay unverified. Different documents; another module's map cannot resolve either source's contradiction.
  • FTLX8574D3BCL PDF p. 2 labels pin 9 VeeR; p. 3 labels it RS1 and says no connection required. It is explicitly unverified rather than choosing one label. The p. 2 figure also prints 1 at the bottom position where the table has pin 10, so that spatial numbering is not used.
  • These are named optical module examples, not universal assignments for copper SFP, DAC, other rates, vendor modules or equipment PCB solder tails. Power ratings and compatibility are not generalized.
SFP-family host connector mechanical identifierp. 2 Diagram of Host Board Connector Block Pin Numbers and Names: host to left with module insertion direction; bezel to right. Do not transfer to a module-bottom view.SCHEMATIC · physical positions unconfirmedNot to scale · check the named wiring and device manual1: VEET (device_specific)12: TFAULT (device_specific)23: TDIS (device_specific)34: SDA (device_specific)45: SCL (device_specific)56: MOD_ABS (device_specific)67: RS0 / NC (not_connected)78: RX_LOS (device_specific)89: RS1 / NC (not_connected)910: VEER (device_specific)1011: VEER (device_specific)1112: RD- (device_specific)1213: RD+ (device_specific)1314: VEER (device_specific)1415: VCCR (device_specific)1516: VCCT (device_specific)1617: VEET (device_specific)1718: TD+ (device_specific)1819: TD- (device_specific)1920: VEET (device_specific)20powergrounddataConfigshieldNCUnknown
Schematic only · physical contact positions unconfirmed. Original drawing · not to scale. Scroll sideways if needed.
Coherent FTLF8536P5xyL SFP28 single-rate 25GbE — source-scoped contact map
PinSignalWhat it doesStatus
1VEETGround reference and return.Device-specific
Sources
2TFAULTControl, detection or configuration connection; check the source and device.Device-specific
Sources
3TDISControl, detection or configuration connection; check the source and device.Device-specific
Sources
4SDAControl, detection or configuration connection; check the source and device.Device-specific
Sources
5SCLControl, detection or configuration connection; check the source and device.Device-specific
Sources
6MOD_ABSControl, detection or configuration connection; check the source and device.Device-specific
Sources
7RS0 / NCNot connected or absent in this named wiring.Not connected
Sources
8RX_LOSSignal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
9RS1 / NCNot connected or absent in this named wiring.Not connected
Sources
10VEERGround reference and return.Device-specific
Sources
11VEERGround reference and return.Device-specific
Sources
12RD-Signal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
13RD+Signal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
14VEERGround reference and return.Device-specific
Sources
15VCCRPower connection (VCCR). Check the specified supply.Device-specific
Sources
16VCCTPower connection (VCCT). Check the specified supply.Device-specific
Sources
17VEETGround reference and return.Device-specific
Sources
18TD+Signal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
19TD-Signal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
20VEETGround reference and return.Device-specific
Sources
Sources (1)

Coherent FTLF8536P5xyV SFP28 dual-rate 10/25GbE

Device-specific wiring. Check your device’s manual before connecting or applying power.

View and evidence limits

p. 2 Diagram of Host Board Connector Block Pin Numbers and Names: host to left with module insertion direction; bezel to right. Do not transfer to a module-bottom view.

  • P200 SFP / SFP+ / SFP28 host — **Partial; internal source conflicts remain** — A: SFP MSA, SFF-8431, SFF-8419/SFF-8402 and Amphenol AOC. B: Broadcom SFP and Coherent SFP+/SFP28 module datasheets. Common supply, management and differential data contacts align. B's Fast Ethernet SFP does not implement the MSA's fault/rate-select functions on 2/7. Legacy SFP 9 is ground; SFP+ and dual-rate SFP28 use a rate-select role. B's single-rate SFP28 explicitly makes 7/9 NC. **A's SFF-8419 rev 2.0a conflicts internally on labels at 7/9; B's Coherent SFP+ datasheet conflicts internally at 9 (VeeR versus RS1).** Those rows stay unverified. Different documents; another module's map cannot resolve either source's contradiction.
  • FTLX8574D3BCL PDF p. 2 labels pin 9 VeeR; p. 3 labels it RS1 and says no connection required. It is explicitly unverified rather than choosing one label. The p. 2 figure also prints 1 at the bottom position where the table has pin 10, so that spatial numbering is not used.
  • These are named optical module examples, not universal assignments for copper SFP, DAC, other rates, vendor modules or equipment PCB solder tails. Power ratings and compatibility are not generalized.
SFP-family host connector mechanical identifierp. 2 Diagram of Host Board Connector Block Pin Numbers and Names: host to left with module insertion direction; bezel to right. Do not transfer to a module-bottom view.SCHEMATIC · physical positions unconfirmedNot to scale · check the named wiring and device manual1: VEET (device_specific)12: TFAULT (device_specific)23: TDIS (device_specific)34: SDA (device_specific)45: SCL (device_specific)56: MOD_ABS (device_specific)67: RS0 (device_specific)78: RX_LOS (device_specific)89: RS1 (device_specific)910: VEER (device_specific)1011: VEER (device_specific)1112: RD- (device_specific)1213: RD+ (device_specific)1314: VEER (device_specific)1415: VCCR (device_specific)1516: VCCT (device_specific)1617: VEET (device_specific)1718: TD+ (device_specific)1819: TD- (device_specific)1920: VEET (device_specific)20powergrounddataConfigshieldNCUnknown
Schematic only · physical contact positions unconfirmed. Original drawing · not to scale. Scroll sideways if needed.
Coherent FTLF8536P5xyV SFP28 dual-rate 10/25GbE — source-scoped contact map
PinSignalWhat it doesStatus
1VEETGround reference and return.Device-specific
Sources
2TFAULTControl, detection or configuration connection; check the source and device.Device-specific
Sources
3TDISControl, detection or configuration connection; check the source and device.Device-specific
Sources
4SDAControl, detection or configuration connection; check the source and device.Device-specific
Sources
5SCLControl, detection or configuration connection; check the source and device.Device-specific
Sources
6MOD_ABSControl, detection or configuration connection; check the source and device.Device-specific
Sources
7RS0Control, detection or configuration connection; check the source and device.Device-specific
Sources
8RX_LOSSignal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
9RS1Control, detection or configuration connection; check the source and device.Device-specific
Sources
10VEERGround reference and return.Device-specific
Sources
11VEERGround reference and return.Device-specific
Sources
12RD-Signal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
13RD+Signal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
14VEERGround reference and return.Device-specific
Sources
15VCCRPower connection (VCCR). Check the specified supply.Device-specific
Sources
16VCCTPower connection (VCCT). Check the specified supply.Device-specific
Sources
17VEETGround reference and return.Device-specific
Sources
18TD+Signal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
19TD-Signal conductor. Pair, polarity and direction follow this named wiring.Device-specific
Sources
20VEETGround reference and return.Device-specific
Sources
Sources (1)

Unknowns stay unknown.

  • The 0.80 mm pitch and two-row construction are example-component facts, not a universal fabrication envelope.
  • No SFP electrical pin map is published in this profile.
  • SFP-family module capability remains module- and host-specific.

Your next step

Use the detail without guessing past its limits.

Source trail

Claims and sources

C200Asource checked

Amphenol identifies an UltraPort SFP-family host connector as a 20-position hot-swappable I/O form used for SFP+ and SFP28 applications.

Amphenol Communications Solutions · UltraPort SFP connector series ↗
SFP series overview · Identification/reference scope only. V36 does not convert this source into a universal pinout, fabrication drawing, electrical approval or end-to-end compatibility verdict.

Back to first citation ↑
C200Bsource checked

Molex product 744410010 documents an SFP/SFP+ host receptacle with 20 loaded circuits, two rows, right-angle orientation and 0.80 mm mating-interface pitch.

Molex · 74441 SFP/SFP+ 20-circuit host connector ↗
Product description and physical fields · Example-component geometry only. It does not establish the module electrical pad assignment or a universal fabrication envelope for every SFP-family connector.

C807Ksource checked

SFP28 SFF-8472-managed interface / SFF-8419: original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

SNIA SFF TWG · SFF-8419 SFP+ Power and Low Speed Interface ↗
pp.15-17 section 7.2.1, Figure 7-1 host view, Figure 7-2 module view, Table 7-1 electrical contact definition · Source scope and unresolved evidence are preserved in the engineering variant.

SNIA SFF TA TWG · SFF-8402 SFP+ 1X Pluggable Transceiver Solutions ↗
pp.8-9 sections5.1.1/5.2: SFP28 SFF-8472 management and SFF-8419 electrical reference · Source scope and unresolved evidence are preserved in the engineering variant.

C807Lsource checked

Amphenol AQP-XPB4-XXX SFP28 AOC end: original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Amphenol · AQP-XPB4-XXX — 100G QSFP28 to 4xSFP28 Active Optical Cable ↗
pp.3-4 sectionIII Pin Assignment, Cable END—SFP28 table/notes; p.8 Appendix A revision · Source scope and unresolved evidence are preserved in the engineering variant.

C807Msource checked

Broadcom AFBR-57E6APZ SFP for FDDI/Fast Ethernet: original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Broadcom / Avago · AFBR-57E6APZ Multimode Small Form Factor Pluggable Transceivers with LC Connector and DMI for FDDI and Fast Ethernet Data Sheet ↗
p. 6, Table 2 Pin Description, pins 1–20 and notes 1–6; Figure 2 on p. 2 gives numbering as viewed through top of board · Source scope and unresolved evidence are preserved in the engineering variant.

C807Nsource checked

Coherent FTLX8574D3BCL SFP+: original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Coherent / Finisar · FTLX8574D3BCL Optical Transceiver Data Sheet ↗
p. 2 host-board connector diagram labels pin 9 VeeR, while p. 3 pin table labels pin 9 RS1 / No connection required; p. 3, I. Pin Descriptions table and notes; p. 2 Diagram of Host Board Connector Block Pin Numbers and Names · Source scope and unresolved evidence are preserved in the engineering variant.

10 source records support this profile. No independent engineering review or hardware validation is claimed.

Evidence behind this page

Scope first. Source second. Approval separate.

10 linked sources · 10 scoped claims · 0 sources with inspection/access flags.

Page scope: Original V37 logical-assignment schematic; not to scale and not a mating-face or manufacturing drawing.

Assessment 2026-10-22 · earliest scheduled source review 2027-01-03. This is a recorded-date assessment, not a live source check. Page-level independent review is not established by this panel.

Inspect 10 source scopes, access limits and dates

S203 · UltraPort SFP connector series

Amphenol Communications Solutions · Manufacturer / product-owner domain · inspected 2026-10-05 · due 2027-01-03

Within inspection window

Scoped support: Identifies the hot-swappable SFP-family host interface as a 20-position connector form used for SFP+ / SFP28 applications.

Not established / limitations: Identification/reference scope only. V36 does not convert this source into a universal pinout, fabrication drawing, electrical approval or end-to-end compatibility verdict.

Locator: SFP series overview

S217 · 74441 SFP/SFP+ 20-circuit host connector

Molex · Manufacturer / product-owner domain · inspected 2026-10-05 · due 2027-01-03

Within inspection window

Scoped support: Example-component engineering source documenting an SFP/SFP+ host receptacle with 20 circuits, two rows and 0.80 mm mating-interface pitch.

Not established / limitations: Example-component geometry only. It does not establish the module electrical pad assignment or a universal fabrication envelope for every SFP-family connector.

Locator: Product description and physical fields

S780 · INF-8074i Specification for SFP (Small Formfactor Pluggable) Transceiver

SFP MSA contributors / SFF Committee (SNIA archive) · Standards-organization domain · inspected 2026-10-21 · due 2027-01-19

Within inspection window

Scoped support: Exact named pinout variant only; not capability or compatibility approval.

Not established / limitations: Source scope and unresolved evidence are preserved in the engineering variant.

Locator: Attached MSA Appendix B, printed pp.20-22 / PDF pp.21-23, Figure 1 and Table 1 Pin Function Definitions with notes

S781 · SFF-8431 SFP+ 10 Gb/s and Low Speed Electrical Interface

SFF Committee (SNIA archive) · Standards-organization domain · inspected 2026-10-21 · due 2027-01-19

Within inspection window

Scoped support: Exact named pinout variant only; not capability or compatibility approval.

Not established / limitations: Source scope and unresolved evidence are preserved in the engineering variant.

Locator: printed p.6 / PDF p.23, Table 3 electrical contact definition and note1; printed p.5 / PDF p.22, Figures1-2

S782 · SFF-8419 SFP+ Power and Low Speed Interface

SNIA SFF TWG · Standards-organization domain · inspected 2026-10-21 · due 2027-01-19

Within inspection window

Scoped support: Exact named pinout variant only; not capability or compatibility approval.

Not established / limitations: Source scope and unresolved evidence are preserved in the engineering variant.

Locator: pp.15-17 section 7.2.1, Figure 7-1 host view, Figure 7-2 module view, Table 7-1 electrical contact definition

S783 · SFF-8402 SFP+ 1X Pluggable Transceiver Solutions

SNIA SFF TA TWG · Standards-organization domain · inspected 2026-10-21 · due 2027-01-19

Within inspection window

Scoped support: Exact named pinout variant only; not capability or compatibility approval.

Not established / limitations: Source scope and unresolved evidence are preserved in the engineering variant.

Locator: pp.8-9 sections5.1.1/5.2: SFP28 SFF-8472 management and SFF-8419 electrical reference

S784 · AQP-XPB4-XXX — 100G QSFP28 to 4xSFP28 Active Optical Cable

Amphenol · Manufacturer / product-owner domain · inspected 2026-10-21 · due 2027-01-19

Within inspection window

Scoped support: Exact named pinout variant only; not capability or compatibility approval.

Not established / limitations: Source scope and unresolved evidence are preserved in the engineering variant.

Locator: pp.3-4 sectionIII Pin Assignment, Cable END—SFP28 table/notes; p.8 Appendix A revision

S785 · AFBR-57E6APZ Multimode Small Form Factor Pluggable Transceivers with LC Connector and DMI for FDDI and Fast Ethernet Data Sheet

Broadcom / Avago · Unclassified publisher domain · inspected 2026-10-21 · due 2027-01-19

Within inspection window

Scoped support: Exact named pinout variant only; not capability or compatibility approval.

Not established / limitations: Source scope and unresolved evidence are preserved in the engineering variant.

Locator: p. 6, Table 2 Pin Description, pins 1–20 and notes 1–6; Figure 2 on p. 2 gives numbering as viewed through top of board

S786 · FTLX8574D3BCL Optical Transceiver Data Sheet

Coherent / Finisar · Unclassified publisher domain · inspected 2026-10-21 · due 2027-01-19

Within inspection window

Scoped support: Exact named pinout variant only; not capability or compatibility approval.

Not established / limitations: Source scope and unresolved evidence are preserved in the engineering variant.

Locator: p. 2 host-board connector diagram labels pin 9 VeeR, while p. 3 pin table labels pin 9 RS1 / No connection required; p. 3, I. Pin Descriptions table and notes; p. 2 Diagram of Host Board Connector Block Pin Numbers and Names

S787 · FTLF8536P5xyz Optical Transceivers — 25GBASE-SR 100m SFP28 Finisar Transceiver

Coherent / Finisar · Unclassified publisher domain · inspected 2026-10-21 · due 2027-01-19

Within inspection window

Scoped support: Exact named pinout variant only; not capability or compatibility approval.

Not established / limitations: Source scope and unresolved evidence are preserved in the engineering variant.

Locator: pp. 2–3, Product Selection and I. Pin Descriptions; pin table and notes on p. 3; ordering suffixes on p. 11

Trace 10 claims to their source records

C200A · P200

Amphenol identifies an UltraPort SFP-family host connector as a 20-position hot-swappable I/O form used for SFP+ and SFP28 applications.

Claim scope: V36 catalogue-expansion identification fact only; not independent technical approval, fabrication data, wiring instruction or end-to-end compatibility proof.

Source links: S203 · Evidence trail → (private workspace)

C200B · P200

Molex product 744410010 documents an SFP/SFP+ host receptacle with 20 loaded circuits, two rows, right-angle orientation and 0.80 mm mating-interface pitch.

Claim scope: V37 engineering-depth sidecar fact; source-checked but not independently human-approved, not a fabrication drawing, and not a safe-substitution or repair instruction.

Source links: S217 · Evidence trail → (private workspace)

C807I · P200

Classic SFP gigabit datacom / INF-8074i: original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Claim scope: Pinout variant only; see comparison and per-contact status. Not fabrication approval.

Source links: S780 · Evidence trail → (private workspace)

C807J · P200

SFP+ transceiver interface / SFF-8431: original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Claim scope: Pinout variant only; see comparison and per-contact status. Not fabrication approval.

Source links: S781 · Evidence trail → (private workspace)

C807K · P200

SFP28 SFF-8472-managed interface / SFF-8419: original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Claim scope: Pinout variant only; see comparison and per-contact status. Not fabrication approval.

Source links: S782 · S783 · Evidence trail → (private workspace)

C807L · P200

Amphenol AQP-XPB4-XXX SFP28 AOC end: original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Claim scope: Pinout variant only; see comparison and per-contact status. Not fabrication approval.

Source links: S784 · Evidence trail → (private workspace)

C807M · P200

Broadcom AFBR-57E6APZ SFP for FDDI/Fast Ethernet: original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Claim scope: Pinout variant only; see comparison and per-contact status. Not fabrication approval.

Source links: S785 · Evidence trail → (private workspace)

C807N · P200

Coherent FTLX8574D3BCL SFP+: original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Claim scope: Pinout variant only; see comparison and per-contact status. Not fabrication approval.

Source links: S786 · Evidence trail → (private workspace)

C807O · P200

Coherent FTLF8536P5xyL SFP28 single-rate 25GbE: original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Claim scope: Pinout variant only; see comparison and per-contact status. Not fabrication approval.

Source links: S787 · Evidence trail → (private workspace)

C807P · P200

Coherent FTLF8536P5xyV SFP28 dual-rate 10/25GbE: original contact normalization. Statuses distinguish comparison agreement, source limits and named-device wiring.

Claim scope: Pinout variant only; see comparison and per-contact status. Not fabrication approval.

Source links: S787 · Evidence trail → (private workspace)

Prepare this page for review → (private workspace)Read the evidence method →

Recorded evidence only. An inspection date, publisher label, source link or generated packet is not independent technical review, hardware testing, fabrication approval or a compatibility verdict.